Feature 15: Increased ventilation

Type Description
Amendment
Type: Amendment
Post Date: 06 May, 2016

In Part 1a, change “Exceed ASHRAE fresh air supply rates…” to “Exceed ASHRAE outdoor air supply rates…”


Feature 16: Humidity control

Type Description
Amendment
Type: Amendment
Post Date: 05 Feb, 2018

In part description, remove: "locker rooms". Add: "changing rooms"


Equivalency
Type: Equivalency
Post Date: 04 Sep, 2017

ASHRAE 55 - Universal Comfort Zone has not been deemed acceptable as an equivalent method for the requirements of Feature 16 Part 1. ASHRAE 55 - Universal Comfort Zone includes a formula to calculate optimal interior relative humidity levels that may fall outside of the range specified in the WELL Building Standard.


Equivalency
Type: Equivalency
Post Date: 21 Aug, 2017

Projects situated in countries where local or regional standards do not pose strict requirements for relative humidity control (e.g. EN-15251) cannot earn points by not complying with the requirements of Feature 16, Part 1. Projects without dehumidification or humidification systems may earn points through Part 1b.


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To limit the growth of pathogens, reduce off-gassing, and maintain thermal comfort by providing the appropriate level of humidity.'


Feature 17: Direct source ventilation

Type Description
Amendment
Type: Amendment
Post Date: 05 Feb, 2018

In part title, remove: "Locker Rooms". Add: "Changing Rooms". In part description, remove: "Locker rooms". Add: "Changing rooms"


Equivalency
Type: Equivalency
Post Date: 13 Dec, 2017

Eco Mark No. 155 has been accepted as an equivalent to Blue Label RAL UZ 171 for Feature 17 Part 1. Note that this equivalency may only be used for projects in Japan.


Equivalency
Type: Equivalency
Post Date: 21 Aug, 2017

Low emission criteria of EPEAT has been accepted as an alternative to Ecologo CCD 035, Blue Angel RAL- UZ 171 or Green Star in Feature 17 Part 1.


Amendment
Type: Amendment
Post Date: 17 Jan, 2017

Under Part 1, change the beginning of the first line to 'All cleaning and chemical storage units, all bathrooms and all rooms that contain printers and copiers…"


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To preserve air quality in occupied spaces through the isolation and proper ventilation of indoor pollution sources and chemical storage areas.'


Verification type
Type: Verification type
Post Date: 10 Feb, 2016

Add annotated mechanical and architectural drawing as required documentation, remove MEP Letter of Assurance, remove on-site spot checks.


Feature 18: Air quality monitoring and feedback

Type Description
Amendment
Type: Amendment
Post Date: 05 Feb, 2018

For Part 2a, remove: "the Air Quality Standards feature". Add: "Part 1: Indoor Air Monitoring"


Amendment
Type: Amendment
Post Date: 20 Oct, 2017

In 06 May, 2016 AAP, remove: "In projects with strict data privacy requirements, the". Add: "The"


Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Add: "(measured at 1.2-1.8 m [4-6 ft] above the floor)" after "once an hour"


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To monitor and effectively remediate indoor air quality issues and inform building managers and occupants of the quality of the indoor environment.'


Alternative Adherence Path
Type: Alternative Adherence Path
Post Date: 06 May, 2016

The requirements of Part 3 (Environmental Measures Display) may be met by hosting the required data on a website accessible to occupants and in locations where the physical display would be located, placing signage indicating the website where the data may be accessed.


Amendment
Type: Amendment
Post Date: 06 May, 2016

In Part 1 description, change “Monitors measure 2 of the following pollutants in a regularly occupied space…” to “Monitors measure 2 of the following pollutants in a regularly occupied or common space…”


Verification type
Type: Verification type
Post Date: 10 Feb, 2016

Add on-site spot checks as required verification.


Feature 19: Operable windows

Type Description
Alternative Adherence Path
Type: Alternative Adherence Path
Post Date: 27 Apr, 2017

For Feature 19, Part 1, a dedicated outdoor terrace can be provided. The terrace must satisfy the following requirements:
a. Must be directly accessible from the tenant space
b. Must be able to accommodate a minimum of 15% of the total regular project occupants
c. Must be adequately shaded to allow occupants to perform their work without significant glare
d. Feature 19, Part 2 and Part 3 must be addressed


Alternative Adherence Path
Type: Alternative Adherence Path
Post Date: 17 Jan, 2017

To fulfill Feature 19, Part 1, projects may provide operable windows to 95% of the regularly occupied spaces (by floor area) in the office, provided that regularly occupied spaces, which do not have windows, have larger doorways to allow fresh air in, when open.


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To increase the supply of high quality outdoor air and promote a connection to the outdoor environment by encouraging occupants to open windows when outdoor air quality is acceptable.'


Amendment
Type: Amendment
Post Date: 06 May, 2016

Change “Every regularly occupied space has operable windows that provide access to fresh air…” to “Every regularly occupied space has operable windows that provide access to outdoor air…”


Verification type
Type: Verification type
Post Date: 10 Feb, 2016

Add Architect Letter of Assurance as required documentation, remove annotated architectural drawing.


Verification type
Type: Verification type
Post Date: 10 Feb, 2016

Add policy document as required documentation, remove Architect Letter of Assurance.


Verification type
Type: Verification type
Post Date: 10 Feb, 2016

Add Owner Letter of Assurance as required documentation, remove Architect Letter of Assurance.


Feature 20: Outdoor air systems

Type Description
Amendment
Type: Amendment
Post Date: 26 Jul, 2017

For Part 1b, remove: "all applicable ASHRAE standards and codes". Add: "ventilation standards used in Feature 03 Ventilation effectiveness"


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To allow buildings to control the outdoor air supply independently from the heating/cooling needs of the building.'


Feature 21: Displacement ventilation

Type Description
Equivalency
Type: Equivalency
Post Date: 21 Aug, 2017

REHVA Guidebook No. 1 (Displacement Ventilation in non-industrial premises) may be used in lieu of the System Performance Evaluation and ASHRAE Guidelines RP-949 for Feature 21, Part 1.


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To improve air quality in the breathing zone of the room and maintain thermal comfort by supplying low velocity outdoor air near the floor and expelling near the ceiling.'


Amendment
Type: Amendment
Post Date: 06 May, 2016

Replace “One of the following is met for projects implementing a displacement ventilation system for heading and/or cooling:” with “Projects implement a displacement ventilation system for heating and/or cooling in which one of the following is met:”


Feature 22: Pest control

Type Description
Alternative Adherence Path
Type: Alternative Adherence Path
Post Date: 27 Apr, 2017

When desk bins are used to comply with Feature 22, Part 1, Requirement b, waste must be emptied at least once per day. Bins must be lined with appropriate liners (e.g. biodegradable liners for the compost bin) that will sufficiently retain all waste and waste residue. Bins must be wiped to remove waste residue when present or at least weekly.


Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Remove: "Inspections". Add: "Visual inspections during performance verification"


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To reduce the presence of pests in buildings and minimize occupant exposure to pest-related allergens.'


Verification type
Type: Verification type
Post Date: 06 May, 2016

Change Part 1 verification type from Visual Inspection to Operations Schedule and Spot Check.


Alternative Adherence Path
Type: Alternative Adherence Path
Post Date: 06 May, 2016

Inquiry: For Part 1b, our garbage cans are integrated into casework. The casework has a 6 inch opening at the top for users to insert waste. The garbage is collected from the garbage cans daily to minimize the time that waste remains in the garbage cans. Will this design meet the requirements of Part 1b?

Ruling: No, the design as described is not approved. The openings are large enough to allow pests to gain access to the garbage and allow for discarded trash to fall outside the garbage receptacle within the casework.


Amendment
Type: Amendment
Post Date: 10 Feb, 2016

In introduction language, remove "and furniture be covered in washable covers" from the last sentence in the second paragraph. The last sentence becomes: "To minimize allergenic pests, this feature requires that pest inspections be conducted regularly and food be stored and sealed."


Feature 23: Advanced air purification

Type Description
Amendment
Type: Amendment
Post Date: 20 Oct, 2017

For Part 1a, add: "or combination particulate/carbon filters" after "Activated carbon filters"


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To improve recirculated indoor air quality through the implementation of advanced air purification strategies.'


Feature 24: Combustion minimization

Type Description
Amendment
Type: Amendment
Post Date: 20 Oct, 2017

Add: "for construction occurring within one year prior to Performance Verification:" after "...the following requirements are met"


Equivalency
Type: Equivalency
Post Date: 20 Oct, 2017

China's GB 6932-2015 Domestic gas instantaneous water heater, Class 5 has been approved for Feature 24 Part 2. It should be noted that the testing protocols in China GB 6932-2015 for humidity and oxygen percentage differ from the requirements in California's South Coast Air Quality Management District rule 1121. However, GB 6932-2015 Domestic gas instantaneous water heater, Class 5 is currently deemed best in class within China.


Equivalency
Type: Equivalency
Post Date: 21 Aug, 2017

The emission standards of Central Pollution Control Board (Government of India) has been accepted as an alternative for California’s South Coast Air Quality Management District rules for pollution in Feature 24 Part 2. However, combustion equipment for which there are no CPCB emission standards must meet California’s South Coast Air Quality Management District rules for pollution.
The following are acceptable alternatives to the requirements of Feature 24 Part 4

  • Emission standards as per Bharat Stage III for Feature 24 Part 4 a
  • Emission standards as per Bharat Stage III or IV for Feature 24 Part 4 b

Equivalency
Type: Equivalency
Post Date: 07 Apr, 2017

The following equivalencies have been approved for Feature 24 Part 4:
1. Non-road diesel engine vehicles - Euro Stage IIIA, US Tier 3 and 2, Japan MoE standards.
2. On road diesel engine vehicles - Euro V (2012) standard.
It should be noted that Euro Stage IIIA, US Tier 3 and 2, Japan MoE and Euro V (2012) standard's allowable emission levels exceed those required in US Tier 4 and US EPA 2007. However, Euro Stage IIIA, US Tier 3 and 2, Japan MoE and Euro V are currently deemed best in class within Hong Kong at this time.
It should be noted that Euro Stage IIIA, US Tier 3 and 2, Japan MoE and Euro V (2012) standard's allowable emission levels exceed those required in US Tier 4 and US EPA 2007. However, Euro Stage IIIA, US Tier 3 and 2, Japan MoE and Euro V are currently deemed best in class within Hong Kong at this time.


Equivalency
Type: Equivalency
Post Date: 20 Mar, 2017

The following European local emission standards have been approved as an acceptable equivalent for Feature 24, Part 4:
1. European Stage IV standard for non-road diesel engine vehicles or the use of non-road diesel engine vehicles equipped with diesel particulate filters (DPF).
2. Euro VI emission standards for on-road engine vehicles or the use of on-road diesel engine vehicles equipped with diesel particulate filters (DPF).


Alternative Adherence Path
Type: Alternative Adherence Path
Post Date: 17 Jan, 2017

Projects that wish to include a gas range within the project scope must provide range hoods with increased exhaust efficiency in order to exhaust combustion byproducts. The range hood must provide at least 100 cubic feet per minute of exhaust air for every 10,000 BTU’s of burner output. If the burner output is unknown or cannot be guaranteed, then the range hood should provide a minimum of 600 cubic feet per minute of exhaust air. In addition, the range hood shall be exhausted directly to the outdoors.


Equivalency
Type: Equivalency
Post Date: 17 Jan, 2017

The following China local standards have been approved as an acceptable alternative for F24, Part 4:
1. China local standard GB20891-2014 for non-road diesel engine vehicles
2. China local standard GB17691-2005 for passenger vehicles and heavy duty trucks
Note that that NOx limits in the China standards are higher then US EPA limits.


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To reduce occupant exposure to combustion-related air pollution from heating and transportation sources.'


Verification type
Type: Verification type
Post Date: 10 Feb, 2016

Add Owner Letter of Assurance as required documentation, remove Architect Letter of Assurance.


Feature 25: Toxic material reduction

Type Description
Equivalency
Type: Equivalency
Post Date: 12 Dec, 2017

Products certified under Good Environmental Choice Australia (GECA) Furniture & Fittings (Level B) (FF v3.0-2017) standard, are considered to meet the toxic material reduction restrictions of Feature 25 Part 1, 2 and 5. Note however that any products certified under Good Environmental Choice Australia (GECA) Furniture & Fittings (Level B) (FF v3.0-2017) standard, have not been accepted as alternatives for the requirements of Feature 25 Part 3, Phthalate (Plasticizers) Limitation. Feature 25 Part 3 requires the limitation of DEHP, DBP, BBP, DINP, DIDP and DNOP phthalates while GECA requires the ban of only DEHP, DBP, DAP and BBP phthalates. Since GECA does not account for the limitation of DINP, DIDP and DNOP, products certified under this GECA standard cannot be deemed as in compliance with Feature 25 Part 3.


Equivalency
Type: Equivalency
Post Date: 12 Dec, 2017

Products certified under Good Environmental Choice Australia (GECA) Furniture, Fittings, Foam and Mattresses (Level A) (FFF&M v3.0-2017) standard, are considered to meet the toxic material reduction restrictions of Feature 25, Parts 1, 2, 3, and 5.


Equivalency
Type: Equivalency
Post Date: 16 Nov, 2017

Global GreenTag Standard v4.0 and PhD Methodology have been accepted as an alternative to the requirements of Feature 25 Part 1. However, Global GreenTag Standard v4.0 and PhD Methodology have no been accepted as an alternative to the requirements of Feature 25 Part 2, 3, 4 and 5.
Note that products which meet the WELL requirements regarding ingredient content will still contribute to these features and may be communicated as such, in accordance with the WELL branding guidelines (https://www.wellcertified.com/sites/default/files/resources/IWBI%20Trade...).


Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Remove: "(Please refer to Table A3 for additional details.)"


Amendment
Type: Amendment
Post Date: 24 Oct, 2016

To the last line of the first paragraph of the feature description, add: "All parts of this feature only apply to materials installed inside the weather proofing membrane of a project. (Please refer to Table A3 for additional details)"


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To minimize the impact of hazardous building material chemicals on indoor air quality and protect the health of manufacturing and maintenance workers.'


Verification type
Type: Verification type
Post Date: 10 Feb, 2016

Add Owner Letter of Assurance as required documentation.


Verification type
Type: Verification type
Post Date: 10 Feb, 2016

Add Contractor Letters of Assurance as required documentation.


Feature 26: Enhanced material safety

Type Description
Equivalency
Type: Equivalency
Post Date: 12 Dec, 2017

The Good Environmental Choice Australia (GECA) Furniture & Fittings, Foam & Mattresses (Level A) (FFF&M v3.0-2017) standard has not been accepted as an alternative to the requirements of Feature 26, Part 1. Note that while most LBC Red List substances are prohibited in the GECA Furniture Level A standard, the Red List prohibits the use of added formaldehyde, but the GECA Furniture Level A standard allows products that contain formaldehyde-based additives, subject to a certain air emissions limit (Section 4.1 Criterion 13). Added formaldehyde was listed in the comparison table provided, but no narrative or note has been provided to address this difference. Additionally, many substances included in the LBC Red List were compared to the GECA Criterion 17, which prohibits any Halogenated organic substances (CFCs, HCFCs, Chloroprene, CPVC, HFRs, PVC, PVDC), but confirmation that specific halogenated organic substances have been covered has not been provided in all cases. If resubmitting this EP with additional clarifications, include a note to confirm that Criterion 17 prohibits that specific Red List prohibited substance, similar to the clarifying statement provided in the “Notes re GECA standard” column of the comparison table for Chlorobenzene.


Equivalency
Type: Equivalency
Post Date: 16 Nov, 2017

The Global GreenTag Standard v4.0 and PhD Methodology are accepted as an alternative to the requirements for Feature 26 Part 1.


Amendment
Type: Amendment
Post Date: 20 Oct, 2017

Remove: “products by cost (including furnishings, built-in furniture, all interior finishes and finish materials”. Add: “all furnishings, built-in furniture, interior finishes, and finish materials (calculated by cost)"


Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Remove: "At least one of the following requirements is met". Add: "At least 25% of products by cost (including furnishings, built-in furniture, all interior finishes and finish materials) meet one or more of the following requirements"


Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Remove: "The project completes all Imperatives in the Materials Petal under the Living Building Challenge 3.0". Add: "Have a Declare: Living Building Challenge Red List Free, Declare: Living Building Challenge Compliant, or Living Product Challenge label"


Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Remove: "At least 25% of products by cost (including furnishings, built-in furniture, all interior finishes and finish materials) are Cradle to Cradle™ Material Health Certified with a V2 Gold or Platinum or V3 Bronze, Silver, Gold or Platinum Material Health Score". Add: "Have a Cradle to Cradle™ Material Health Certified with a V2 Gold or Platinum or V3 Bronze, Silver, Gold or Platinum Material Health Score."


Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Remove: "At least 25% of products by cost (including furnishings, built-in furniture, all interior finishes and finish materials) have no GreenScreen® Benchmark 1, List Translator 1 or List Translator Possible 1 substances over 1,000 ppm, as verified by a qualified Ph.D. toxicologist or Certified Industrial Hygienist". Add: "Have no GreenScreen® Benchmark 1, List Translator 1 or List Translator Possible 1 substances over 1,000 ppm, as verified by a qualified Ph.D. toxicologist or Certified Industrial Hygienist"


Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Remove: "At least 25% of products by cost (including furnishings, built-in furniture, all interior finishes and finish materials) meet some combination of the certifications described in requirements b and c".


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To minimize the impact of hazardous building material ingredients on indoor air quality and protect the health of manufacturing and maintenance workers.'


Verification type
Type: Verification type
Post Date: 10 Feb, 2016

Add Contractor Letter of Assurance as required documentation, add Owner Letter of Assurance as required documentation.


Feature 27: Antimicrobial activity for surfaces

Type Description
Amendment
Type: Amendment
Post Date: 05 Feb, 2018

In part title, remove: "Locker Room". Add: "Changing Room". In part description, remove: "locker rooms". Add: "changing rooms"


Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Remove: "that has an output of at least 4 mW/cm²" after "UV cleaning device"


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To reduce occupant exposure to both harmful pathogens and hazardous cleaning agents.'


Verification type
Type: Verification type
Post Date: 10 Feb, 2016

Add annotated architectural drawing or operations schedule as required documentation, remove architect Letter of Assurance.


Feature 28: Cleanable environment

Type Description
Amendment
Type: Amendment
Post Date: 05 Feb, 2018

In part title, remove: "Locker Rooms". Add: "Changing Rooms". In part description, remove: "locker rooms". Add: "changing rooms"


Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Remove: "Free of sharp internal angles, corners and crevices". Add: "Free of crevices and other hard-to-reach places"


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To reduce occupant exposure to pathogens on high-touch surfaces.'


Verification type
Type: Verification type
Post Date: 10 Feb, 2016

Add on-site spot checks as required verification.


Verification type
Type: Verification type
Post Date: 10 Feb, 2016

Add Contractor Letters of Assurance as required documentation.


Feature 29: Cleaning equipment

Type Description
Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To reduce occupant exposure to both harmful pathogens and hazardous chemicals through the use of high quality cleaning equipment and the proper storage of cleaning agents.'


Amendment
Type: Amendment
Post Date: 10 Feb, 2016

Remove Part 1b. Update part lettering by changing “c. Mops do not have to be wrung by hand.” to “b. Mops do not have to be wrung by hand”, and changing "d. Vacuum cleaners contain filters with a HEPA rating." to "c. Vacuum cleaners contain filters with a HEPA rating."


Feature 30: Fundamental water quality

Type Description
Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To limit the presence of sediment and water-borne pathogens in water designated for human contact.'


Amendment
Type: Amendment
Post Date: 06 May, 2016

In Part 1, change “Turbidity of the water sample is less than 0.3 NTU” to “Turbidity of the water sample is less than 1.0 NTU”.


Feature 31: Inorganic contaminants

Type Description
Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To limit the presence of inorganic contaminants in drinking water.'


Amendment
Type: Amendment
Post Date: 06 May, 2016

Change “All water being delivered to the project area for human consumption meets the following limits:” to “All water being delivered to the project area for human consumption (at least one water dispenser per project) meets the following limits:


Feature 32: Organic contaminants

Type Description
Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To limit the presence of organic contaminants in drinking water.'


Amendment
Type: Amendment
Post Date: 06 May, 2016

Change “All water being delivered to the project area for human consumption meets the following limits:” to “All water being delivered to the project area for human consumption (at least one water dispenser per project) meets the following limits:


Feature 33: Agricultural contaminants

Type Description
Amendment
Type: Amendment
Post Date: 26 Jul, 2017

Remove "Nitrate less than 10 mg/L nitrogen". Add "Nitrate less than 50 mg/L (10 mg/L as nitrogen)"


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To limit the presence of agricultural contaminants in drinking water.'


Amendment
Type: Amendment
Post Date: 06 May, 2016

Change “All water being delivered to the project area for human consumption meets the following limits:” to “All water being delivered to the project area for human consumption (at least one water dispenser per project) meets the following limits:


Feature 34: Public water additives

Type Description
Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To limit the presence of certain disinfectants, disinfection byproducts and fluoride in drinking water.'


Amendment
Type: Amendment
Post Date: 06 May, 2016

Change “All water being delivered to the project area for human consumption or showers/baths meets the following limits:” to “All water being delivered to the project area for human consumption (at least one water dispenser per project) and showers/baths meets the following limits:


Amendment
Type: Amendment
Post Date: 06 May, 2016

Change “All water being delivered to the project area for human consumption meets the following limits:” to “All water being delivered to the project area for human consumption (at least one water dispenser per project) meets the following limits:


Feature 35: Periodic water quality testing

Type Description
Interpretation
Type: Interpretation
Post Date: 24 Oct, 2016
Inquiry: Feature 35 (Periodic Water Quality Testing) Part 1 (Quarterly Testing) requires the project team to test for metals/metalloids on a quarterly basis. How should this testing be conducted?
Ruling: Testing procedures must follow the testing protocol outlined in the WELL Performance Verification Guidebook for Feature 31 (Inorganic Contaminants). If possible, sample points that have not been selected in the previous three quarters should be used.
Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To maintain high quality water through regular water quality monitoring and remediation.'


Feature 36: Water treatment

Type Description
Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Remove: "or showers/baths"


Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Remove: "or showers/baths"


Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Remove: "or showers/baths"


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To improve water quality by requiring the use of water treatment systems.'


Amendment
Type: Amendment
Post Date: 10 Feb, 2016

In Part 2a, remove "Filter rated to remove suspended solids." And replace with "Filter rated to remove suspended solids with pore size 1.5 µm or less."


Amendment
Type: Amendment
Post Date: 10 Feb, 2016

In Part 3b, remove "NSF filter rated to remove" and replace with "Filter rated by the NSF to remove"


Feature 37: Drinking water promotion

Type Description
Alternative Adherence Path
Type: Alternative Adherence Path
Post Date: 24 Oct, 2016

For regularly occupied spaces that are not within 30 meters (100 feet) of a drinking water station, pitchers of filtered water and glasses may be provided that are monitored and refilled through the day. The Operations Schedule for the project must include information regarding the provision (location and quantities) of water and the monitoring and refilling of pitchers if this strategy is used.


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To promote the consumption of water by making high quality drinking water easily accessible to occupants.'


Feature 38: Fruits and vegetables

Type Description
Amendment
Type: Amendment
Post Date: 20 Oct, 2017

For Part 1b, add: "(containing no added sugar)" after "...options are fruits"


Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Remove: "Salad bar or a similar salad-providing section which is positioned away from the walls, allowing 360° access". Add: "Salad bar or similar salad-providing section, positioned in a visible and accessible location"