- Air
- Ventilation effectiveness
Ventilation effectiveness
- 01 Air quality standards
- 02 Smoking ban
- 03 Ventilation effectiveness
- 04 VOC reduction
- 05 Air filtration
- 06 Microbe and mold control
- 07 Construction pollution management
- 08 Healthy entrance
- 09 Cleaning protocol
- 10 Pesticide management
- 11 Fundamental material safety
- 12 Moisture management
- 13 Air flush
- 14 Air infiltration management
- 15 Increased ventilation
- 16 Humidity control
- 17 Direct source ventilation
- 18 Air quality monitoring and feedback
- 19 Operable windows
- 20 Outdoor air systems
- 21 Displacement ventilation
- 22 Pest control
- 23 Advanced air purification
- 24 Combustion minimization
- 25 Toxic material reduction
- 26 Enhanced material safety
- 27 Antimicrobial activity for surfaces
- 28 Cleanable environment
- 29 Cleaning equipment
- P9 Advanced cleaning

Ventilation effectiveness
To ensure adequate ventilation and high indoor air quality.
Post Date: 16 Mar, 2020 Status: Approved The Article R4222-6 of the French Work Code (Code du Travail) has been deemed acceptable for ASHRAE 62.1-2013 of Part 1 for France. |
Post Date: 05 Jun, 2019 Status: Approved ASHRAE Standard 170-2008 has been accepted as an alternative to meet the requirements of Feature 3 - Ventilation Effectiveness, Part 1 - Ventilation Design for healthcare facilities. Note that all spaces not covered in ASHRAE 170-2008 must follow ventilation rates described in ASHRAE 62.1-2010 or later. |
Post Date: 30 Nov, 2018 Status: Approved UK Building Regulations Part F has been accepted as an equivalent for ASHRAE 62.2-2013 of Feature 03, Part 4a for supply air ventilation requirements. |
Post Date: 29 May, 2018 Status: Not Approved A thermal comfort survey has not been accepted as an equivalent for the requirements of Feature 03 Part 3. Note that the intent of Feature 03 is to ensure adequate ventilation and high indoor air quality. Additionally, the reference standard for this feature is ASHRAE 62.1-2013: Ventilation for Acceptable Indoor Air Quality, not ASHRAE 55-2013. |
Post Date: 29 May, 2018 Status: Not Approved ASHRAE Standard 62.1-2007 has not been accepted as an equivalent for the requirements of Feature 03 Part 1 and 3. Note that the ventilation requirements for all space types are not equivalent between ASHRAE Standard 62.1 versions 2007 and 2013. Therefore, these reference standards cannot be considered equivalent for all projects. |
Post Date: 11 May, 2018 Status: Not Approved Singapore SS 553:2016 CP Standard has not been accepted as an equivalent for ASHRAE 62.1-2013 of Feature 03. SS 553 Table 1 does not address all applicable and expected space types within an office occupancy. Note also that all Equivalencies are precedent-setting meaning that review of potential equivalent standards or codes cannot be conducted on a project-specific basis. Equivalency proposals must address the variety of project and space types present in the original code or standard. Further, in some cases, the ventilation rates listed in SS 553 Table 1 appear to be less than the default ventilation rates listed in ASHRAE 62.1-2013 Table 6.2.2.1 for the same occupancy types. |
Post Date: 28 Mar, 2018 Status: Not Approved Singapore SS 553 (2016) CP Standard has not been accepted as an equivalent for ASHRAE 62.1-2013 of Feature 03. Note the building/occupancy types indicated in the Outdoor Air Supply Requirements (Table 1) is not sufficient to cover all buildings and space types for all projects in Singapore. |
Post Date: 05 Feb, 2018 Status: Approved CIBSE Guide A has been accepted as an alternative for the requirements in ASHRAE 62.1 2013 for Feature 3 Part 1 |
Post Date: 20 Mar, 2017 Status: Approved EN 13779, section A. 15. 2, Table A.10 may be used to comply with Feature 03, Part 2. Note, projects must adhere to Indoor Air Category IDA 1 or 2. |
Post Date: 24 Oct, 2016 Status: Approved CEN Standards EN 15251:2007 and EN 16798-3:2017 may be used in lieu of ASHRAE 62.1-2013 for Feature 03, Part 1. Projects must meet Category I or II as described in the standards. |