76. Thermal comfort
To promote occupant productivity and ensure a sufficient level of thermal comfort.
Post Date: 09 Feb, 2017 Status: Approved Multifamily residential projects may certify when not supplying central-system air conditioning or air conditioning units in individual dwelling units, with the following conditions:- Outdoor air is supplied at a volume to meet Feature 3 Part 4 and is filtered to meet Feature 5 Part 2.- The developer allocates spaces for tenant-owned, supplemental air conditioning units to be installed.- The developer supplies all occupants with tenant guidelines for selecting a high-performance air conditioner unit to maximize comfort and optimize efficiency. The guidelines should detail the importance of local thermal comfort standards including environmental factors of air temperature, humidity, radiant temperature, air speed; and personal factors of metabolic rate and clothing insulation.- Projects using this option are limited to Gold level certification, no matter how many optimizations are achieved. |
Post Date: 17 Jan, 2017 Status: Approved Core and Shell residential projects may fulfill the requirements of Feature 76 by providing a narrative of how the residential units meet local thermal comfort standards (environmental factors: air temperature, humidity, radiant temperature, air speed and personal factors: metabolic rate and clothing insulation) or by providing an allowance for tenants to select an air conditioning unit of their choice from options, which would allow the unit to meet the thermal comfort requirements. |
Post Date: 06 May, 2016 Status: Approved ISO 7730:2005 and/or CEN Standard EN 15251:2007 may be used in lieu of ASHRAE 55-2003 Sections 5.3 and 5.4. The requirements of these standards must be met in all spaces, rather than 75% of regularly occupied spaces in the project. When selecting either ISO 7730:2005 or CEN Standard EN 15251:2007, the most appropriate standard must be selected for the space. Note that some naturally ventilated spaces may not qualify to use CEN Standard EN 15251:2007 if certain criteria are not met.In addition, when utilizing CEN Standard EN 15251:2007, the project must comply with either Category I or Category II as described in Table A.1 of the standard in order to be within +/- 0.5 of the PMV for the space. |
Post Date: 06 May, 2016 Status: Not Approved Inquiry: In residential units, are the requirements of Feature 76 met if individual unit controls for heating are provided?Ruling: No, an exemption from ASHRAE 55 requirements may not be granted in residential units if individual unit controls are provided. It is typical for each unit in a multifamily residential development to have individual control over space temperatures with controls allowing occupants to adjust temperatures. In order to rely on the controllability of the systems as an alternative strategy, it must be demonstrated that the local controls allow occupants to set conditions within the unit to meet ASHRAE 55. |
- 72 Accessible design
- 73 Ergonomics: visual and physical
- 74 Exterior noise intrusion
- 75 Internally generated noise
- 76 Thermal comfort
- 77 Olfactory comfort
- 78 Reverberation time
- 79 Sound masking
- 80 Sound reducing surfaces
- 81 Sound barriers
- 82 Individual thermal control
- 83 Radiant thermal comfort
- P4 Impact reducing flooring