Appendix D: Feature Types and Verification Methods
Parts of the WELL Building Standard fall into one of three categories with respect to the interventions necessary for their completion – design elements, protocols or performance standards. Design standards require that a specific technology or design strategy be used. Protocols are also prescriptive, but for building or company policies or schedules. Performance-based standards mandate environmental conditions and therefore are affected by both building design and operation. They are also technology- and practice-neutral, allowing flexibility in how a project meets acceptable quantified thresholds.
The following table also displays the type of documentation relevant (if any) for each Part of a Feature. Project teams should consult this table to understand what document needs to be submitted to demonstrate that the Part has been satisfied, or if no action is necessary because an assessor will check the Part on-site during the Performance Verification.
Air
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Precautionary Material Selection |
Architect | ||
PART 2 (Performance) Standards for Particulate Matter and Inorganic Gases |
Performance Test | ||
PART 3 (Performance) Below-Grade Air Quality Standards |
Performance Test | ||
PART 4 (Performance) Operational Kitchen Air Quality |
Performance Test |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Protocol) Meal Sizes |
Operations Schedule | Spot Check | |
PART 2 (Protocol) Outdoor Smoking Ban |
Auditor Inspection | ||
PART 3 () Smoke-Free Campus |
Architect | Spot Check |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Permanent Entryway Walk-Off Systems |
Auditor Inspection | ||
PART 2 (Design) Demand Controlled Ventilation |
MEP | ||
PART 3 (Design) System Balancing |
Commissioning Report | ||
PART 4 () Ventilation Rates for Residences |
MEP |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Protocol) Duct Protection |
Contractor | ||
PART 2 (Design) Interior Adhesives and Sealants |
Architect | ||
PART 3 (Design) Flooring |
Architect | ||
PART 4 (Design) Insulation |
Architect | ||
PART 5 (Design) Furniture and Furnishings |
Architect |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Filter Accommodation |
MEP | Spot Check | |
PART 1 (Design) Cooling Coil Mold Reduction |
MEP | Spot Check | |
PART 3 (Design) Air Filtration Maintenance |
Operations Schedule |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 2 (Performance) Mold Inspections |
Auditor Inspection | ||
PART 5 (Design) Urea-Formaldehyde Restriction |
Architect |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Protocol) Pesticide Use |
Operations Schedule | ||
PART 2 (Protocol) Filter Replacement |
Contractor | ||
PART 3 (Protocol) VOC Adsorption Management |
Contractor | ||
PART 4 (Protocol) Construction Equipment |
Contractor | ||
PART 5 (Protocol) Dust Containment and Removal |
Contractor |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Interior Paints and Coatings |
Architect | ||
PART 2 (Design) Entryway Air Seal |
Auditor Inspection | ||
PART 3 (Design) Playing Field Staging Area |
Architect | Spot Check |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Cold Storage |
Architect | Spot Check |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 2 (Design) Particle Filtration |
MEP | Spot Check |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Asbestos and Lead Restriction |
Architect | ||
PART 1 (Protocol) Air Flush |
Contractor | ||
PART 3 (Design) Asbestos Abatement |
Remediation Report | ||
PART 4 (Design) Polychlorinated Biphenyl Abatement |
Remediation Report | ||
PART 5 (Design) School Playground Equipment Safety |
Architect |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Healthy Sunlight Exposure |
Architectural Drawing | ||
PART 2 (Design) Interior Bulk Water Damage Management |
MEP | ||
PART 3 (Design) Capillary Water Management |
Architect | ||
PART 4 (Design) Wetting by Condensation |
Architect |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Nature Incorporation |
Architectural Drawing | Spot Check |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Protocol) JUST Participation |
Policy Document | Spot Check | |
PART 2 () Leak Tests for Residences |
Contractor |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Protocol) Indoor Smoking Ban |
Policy Document |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Indoor Air Monitoring |
MEP | ||
PART 2 (Design) Shower Moisture Barrier |
Architectural Drawing |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Material Information |
Architect | ||
PART 1 (Design) Pollution Isolation and Exhaust |
MEP | Spot Check | |
PART 2 () Exhaust Hood Design Guidelines |
MEP | ||
PART 3 () Makeup air system design |
MEP | ||
PART 4 (Design) Appliance Guidelines |
Architect | ||
PART 5 (Design) Locker Rooms |
MEP |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Ventilation Design |
MEP | ||
PART 2 (Protocol) Air Data Record Keeping and Response |
Operations Schedule | ||
PART 3 (Design) Environmental Measures Display |
Auditor Inspection |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Relative Humidity |
MEP | Spot Measurement | |
PART 2 (Design) Outdoor Air Measurement |
Architect | Spot Check | |
PART 3 (Design) Window Operation Management |
Architect | Spot Check |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Source Separation |
Architectural Drawing |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Dedicated Outdoor Air Systems |
MEP | ||
PART 2 (Design) System Performance |
MEP |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Protocol) Equipment and Cleaning Agents |
Operations Schedule | ||
PART 2 (Performance) Pest Inspection |
Auditor Inspection |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Carbon Filtration |
MEP | Spot Check | |
PART 1 (Protocol) Quarterly Testing |
Operations Schedule | ||
PART 3 (Protocol) Air Quality Maintenance |
Operations Schedule |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Increased Fresh Air Supply |
MEP | ||
PART 2 (Design) Low-Emission Combustion Sources |
MEP | ||
PART 3 (Protocol) Engine Exhaust Reduction |
Auditor Inspection |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Perfluorinated Compound Limitation |
Architect | ||
PART 1 (Design) Appliance and Heater Combustion Ban |
Architect | Spot Check | |
PART 2 (Design) Flame Retardant Limitation |
Architect | ||
PART 3 (Design) Phthalate (Plasticizers) Limitation |
Architect | ||
PART 4 (Design) Isocyanate-Based Polyurethane Limitation |
Architect |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Full Control |
Architectural Drawing | Spot Check |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Pest Reduction |
Auditor Inspection | ||
PART 2 (Design) Locker Room Coating |
Contractor |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Protocol) Advanced Cleaning Protocols |
Operations Schedule | ||
PART 2 (Design) Cleanability |
Architect | Spot Check | |
PART 3 (Design) Cleanable Locker Rooms |
Architect |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 2 (Design) Sidewalks |
|||
PART 2 (Design) Lead Abatement |
Remediation Report | ||
PART 3 (Design) Crosswalks |
Architect | Architectural Drawing | |
PART 4 () Safe Routes to School |
Architect | Architectural Drawing | |
PART 5 () Playgrounds |
Architect | Architectural Drawing |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Protocol) Mind and Behavior Support |
Policy Document |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 2 () Sink Operations |
Auditor Inspection |
Water
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Material Properties |
Architect | ||
PART 2 (Design) Chemical Storage |
Auditor Inspection |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Performance) Sediment |
Performance Test | ||
PART 1 (Performance) Organic Pollutants |
Performance Test |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Organic Chemical Removal |
MEP | Spot Check |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Performance) Dissolved Metals |
Performance Test |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 2 (Performance) Fertilizers |
Performance Test | ||
PART 2 (Performance) Microorganisms |
Performance Test |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Performance) Disinfectants |
Performance Test | ||
PART 1 (Performance) Herbicides and Pesticides |
Performance Test | ||
PART 2 (Performance) Disinfectant Byproducts |
Performance Test | ||
PART 3 (Performance) Fluoride |
Performance Test |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Sufficient Lighting |
|||
PART 2 (Protocol) Water Data Record Keeping and Response |
Operations Schedule |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 2 (Design) Sediment Filter |
MEP | Spot Check | |
PART 2 (Design) Drinking Water Access |
Architect | Spot Check | |
PART 3 (Design) Microbial Elimination |
MEP | Spot Check | |
PART 4 (Design) Water Quality Maintenance |
Operations Schedule |
Nourishment
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Performance) Drinking Water Taste Properties |
Performance Test | ||
PART 1 (Design) Circadian Lighting |
Auditor Inspection | ||
PART 3 (Protocol) Water Dispenser Maintenance |
Operations Schedule | ||
PART 4 (Design) Outdoor Drinking Water Access |
Architect |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Protocol) Refined Ingredient Restrictions |
Operations Schedule | Spot Check | |
PART 2 (Protocol) Fruit and Vegetable Promotion |
Operations Schedule | Spot Check |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Protocol) Cooking Material |
Operations Schedule | Spot Check | |
PART 2 (Protocol) Trans Fat Ban |
Operations Schedule | Spot Check | |
PART 3 (Performance) Fryer Oil |
Performance Test | ||
PART 4 (Design) Beverages for Elementary and Middle School |
Architect | ||
PART 5 (Design) Beverages for High School and Adult Education |
Architect | ||
PART 6 (Design) Ingredients Restrictions for Schools |
Architect |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 3 (Design) Communal Cooking Area |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Protocol) Cleaning Plan for Occupied Spaces |
Operations Schedule | ||
PART 2 (Protocol) Contamination Reduction |
Auditor Inspection | ||
PART 3 (Design) Sink Dimensions |
Architect | Spot Check | |
PART 4 (Design) Hand Washing Station Location |
Architect |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) High-Touch Surface Coating |
Architect | ||
PART 2 (Protocol) Food Preparation Separation |
Operations Schedule | Spot Check | |
PART 3 (Design) Residential Kitchen Sinks |
Auditor Inspection |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Gardening Space |
Architect | Spot Check |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Protocol) Sustainable Agriculture |
Operations Schedule | ||
PART 2 () Healthy Cooking Guidelines |
Auditor Inspection |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Protocol) Fruit and Vegetable Variety |
Operations Schedule | Spot Check | |
PART 2 (Protocol) Nutritional Messaging |
Auditor Inspection | ||
PART 3 (Design) Healthy Choices Promotion |
Architect |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Protocol) Food Allergy Labeling |
Operations Schedule | Spot Check | |
PART 2 (Protocol) Cutting Surfaces |
Operations Schedule | Spot Check | |
PART 3 (Protocol) Banned Plastics |
Operations Schedule | ||
PART 4 () Containers for Prepared Food |
MEP |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Protocol) Advertising and Environmental Cues |
Auditor Inspection | ||
PART 2 (Protocol) Dinnerware Sizes |
Operations Schedule | Spot Check |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Protocol) Detailed Nutritional Information |
Auditor Inspection |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Storage Capacity |
Architect | Spot Check | |
PART 2 (Protocol) Humane Agriculture |
Operations Schedule |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Protocol) Artificial Substance Labeling |
Operations Schedule | Spot Check | |
PART 2 (Design) Temperature Control |
Architect | Spot Check | |
PART 3 (Protocol) Oil Storage |
Operations Schedule | ||
PART 4 (Protocol) Kitchen Food Safety |
Architect | Operations Schedule |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Performance) Exterior Lighting |
Architect | ||
PART 2 (Design) Planting Support |
Architect | Spot Check |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Displacement Ventilation Design and Application |
MEP | ||
PART 2 (Protocol) Innovation 2 Support |
Innovation Proposal |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Assessment Scorecard |
Architect | ||
PART 2 (Design) Class Size Caps for Elementary School |
Architect |
Light
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Eating Spaces |
Architectural Drawing | ||
PART 1 (Protocol) Health Benefits |
Policy Document | ||
PART 3 (Design) Lunch Breaks for Schools |
Architect |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Melanopic Light Intensity for Work Areas and Adult Education |
Architect | Spot Measurement | |
PART 2 (Design) Task Lighting |
Architect | Spot Measurement | |
PART 3 () Commercial Kitchen Lighting |
Architect | ||
PART 4 () Visual Acuity in Living Environments |
Architect | ||
PART 5 () Visual Acuity for Learning |
Architect |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Color Rendering Index |
Architect | ||
PART 2 (Performance) Melanopic Light Intensity in Living Environments |
Performance Test | ||
PART 3 (Performance) Melanopic Light Intensity in Breakrooms |
Performance Test | ||
PART 4 (Design) Melanopic Light Intensity in Learning Areas |
Architect |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Working and Learning Area Surface Reflectivity |
Architect |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Wall Construction Specifications |
Architect | ||
PART 2 (Design) Daylight Management |
Architect | Spot Check |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Automated Sunlight Control |
Architect |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Lamp Shielding |
Architect |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 2 () Bedroom Wall and Ceiling Lightness |
Architect | ||
PART 3 () Living Space Wall and Ceiling Lightness |
Architect | ||
PART 3 () Safe Nighttime Navigation Lighting |
Auditor Inspection |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 2 (Design) Responsive Light Control |
Architect | ||
PART 2 (Design) Air Sanitization |
MEP | Spot Check |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Lease Depth |
Architectural Drawing | Spot Check | |
PART 1 (Design) Bulk Water – Exterior Management |
Architect |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 2 (Performance) Sound Masking Limits |
Performance Test |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Healthy Food Access |
|||
PART 1 (Protocol) Food Alternatives |
Operations Schedule |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 () Window Light Elimination |
Auditor Inspection | ||
PART 2 () Electric Light Elimination |
Auditor Inspection |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) ADA Regulations |
Architect |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 2 (Design) Windows and Workspaces |
Architectural Drawing | Spot Check |
Fitness
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Visual Acuity for Working and Adult Education |
Architect | Spot Measurement | |
PART 2 (Design) Window Transmittance in Working and Learning Areas |
Architect | ||
PART 3 (Design) Uniform Color Transmittance |
Architect | ||
PART 4 (Design) Window Sizes for Living Spaces |
Architect |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Active Workstations |
Auditor Inspection | ||
PART 2 (Design) Stair Promotion |
Auditor Inspection | ||
PART 3 (Design) Facilitative Aesthetics |
Auditor Inspection |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Protocol) Professional Fitness Programs |
Policy Document | ||
PART 2 (Protocol) Sedentary Behavior Reduction |
Policy Document |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Ventilated Thermal Environment |
MEP | Spot Measurement | |
PART 2 (Protocol) Fitness Education |
Policy Document | ||
PART 3 (Protocol) Physical Activity Breaks |
Policy Document |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Stair Accessibility |
Auditor Inspection | ||
PART 2 (Design) Pedestrian Promotion |
Architect | Spot Check | |
PART 3 (Design) Walk Score® |
Architect |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Cardiorespiratory Exercise Equipment |
Auditor Inspection | ||
PART 2 (Design) External Exercise Spaces |
Architect | ||
PART 3 () Physical Activity Spaces for Schools |
Architect | Architectural Drawing | |
PART 9 () (PENDING) Residential Site Space Designation |
Auditor Inspection |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Bicycle Storage and Support |
Auditor Inspection | ||
PART 1 (Protocol) Activity Incentive Programs |
Policy Document | ||
PART 3 (Design) Bicycle Storage Facilities for Schools |
Architect |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 2 (Design) Muscle-strengthening Exercise Equipment |
Auditor Inspection | ||
PART 2 (Design) Post Commute and Workout Facilities |
Auditor Inspection | ||
PART 3 (Design) Age-Approriate Equipment |
Architect |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 2 (Design) Healthy Food Convenience |
Architect |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Protocol) Sensors and Wearables |
Policy Document |
Comfort
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Site Space Designation for Offices |
Architectural Drawing | ||
PART 2 (Design) Prevalent Standing Desks |
Auditor Inspection |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 2 (Design) Desk Height Flexibility |
Auditor Inspection | ||
PART 3 (Design) Seat Flexibility |
Auditor Inspection | ||
PART 4 (Design) Standing Support |
Architect | Spot Check |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Performance) Reverberation Time |
Performance Test | ||
PART 2 (Performance) Sound Pressure Level in Residences |
Performance Test | ||
PART 3 (Performance) Noise Criteria in Living Spaces [DELETE] |
Performance Test | ||
PART 3 (Protocol) Acoustical Narrative |
Owner | Policy Document | |
PART 4 (Design) Sound Pressure Level in Schools |
Architect |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Protocol) Acoustic Planning |
Architect | ||
PART 1 (Design) Ceilings |
Architect | ||
PART 2 (Performance) Mechanical Equipment Sound Levels |
Performance Test | ||
PART 3 (Performance) Mechanical Equipment Sound Levels in Sensitive Rooms |
Auditor Inspection | ||
PART 4 (Design) Best-Practice HVAC Installation |
Contractor | Spot Check | |
PART 5 (Design) HVAC Sound Ratings |
MEP |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Protocol) Free Address |
Policy Document | ||
PART 2 (Design) Natural Thermal Adaptation |
MEP | Spot Measurement | |
PART 3 () Thermal Comfort in the Kitchen |
MEP |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 () Handwashing Station Location |
Auditor Inspection |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 2 (Performance) Reverberation Time for Learning Spaces |
Performance Test | ||
PART 6 (Performance) Noise Criteria in Schools |
Performance Test |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Sound Masking Use |
Architect | ||
PART 1 (Protocol) Stakeholder Charrette |
Policy Document |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Floor Construction |
Architect | ||
PART 2 (Design) Walls |
Architect | ||
PART 3 (Design) School Ceilings |
Architect |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 2 (Design) Doorway Specifications |
Architect | ||
PART 2 (Protocol) Information Reporting |
Policy Document | ||
PART 3 (Design) Wall Construction Methodology |
Contractor | ||
PART 4 (Design) Noise Intrusion Mitigation |
Architect | Spot Check | |
PART 5 (Design) Residential Acoustic Privacy |
Architect | ||
PART 6 (Design) Wall Construction Specifications for Schools |
Architect |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Lobbies and Other Common Public Spaces |
MEP | ||
PART 2 (Protocol) Personal Thermal Comfort Devices |
Auditor Inspection |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Window Sizes for Working and Learning Spaces |
Architectural Drawing | Spot Check | |
PART 2 (Design) Dawn Simulation |
Architect |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Visual Ergonomics |
Auditor Inspection |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Performance) Standards for Volatile Substances |
Performance Test |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) View Window Shading |
Architect | Spot Check |
Mind
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Performance) Sound Pressure Level |
Performance Test | ||
PART 2 (Design) Offices and Other Regularly Occupied Spaces |
MEP |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Protocol) Non-Workplace Sleep Support |
Policy Document | ||
PART 2 (Protocol) Health and Wellness Library |
Auditor Inspection | ||
PART 3 (Design) Health and Wellness Narrative |
Architect |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 2 (Protocol) Development Plan |
Policy Document | ||
PART 3 (Protocol) Stakeholder Orientation |
Policy Document | ||
PART 3 (Protocol) Family Support |
Policy Document |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Protocol) Occupant Survey Content |
Policy Document |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Beauty Mindful Design |
Architectural Drawing | Spot Check | |
PART 2 (Design) Pattern Incorporation |
Architectural Drawing | Spot Check | |
PART 3 (Design) Nature Interaction |
Architectural Drawing | Spot Check |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Outdoor Biophilia |
Architect | Spot Check | |
PART 2 (Design) Privacy |
Architect | Spot Check | |
PART 3 (Design) Space Management |
Architect | Spot Check | |
PART 4 (Protocol) Workplace Sleep Support |
Architect | Spot Check |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Ceiling Height |
Architectural Drawing | Spot Check | |
PART 2 (Protocol) Delayed Start |
Architect | Architectural Drawing |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 2 (Design) Break Area Furnishings |
Architect |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Protocol) Innovation 1 Proposal |
Innovation Proposal | ||
PART 2 (Design) Community Immunity |
Architect |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Unit Allocation |
Policy Document | ||
PART 1 (Protocol) Parental Leave |
Policy Document | ||
PART 2 (Protocol) Employer Supported Child Care |
Policy Document |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Protocol) Hand Washing Supplies |
Operations Schedule | Spot Check |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 2 (Protocol) Stress Management |
Policy Document | ||
PART 3 (Protocol) Mind and Behavior Support for Students |
Architect | Architectural Drawing |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 2 (Protocol) Charitable Contributions |
Policy Document |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Workstation Orientation |
Auditor Inspection | ||
PART 2 (Design) Accessible Information |
Auditor Inspection |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Protocol) Travel Policy |
Policy Document |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Stimuli Management |
Architect | Spot Check | |
PART 1 (Design) Air Leakage Testing |
Commissioning Report | ||
PART 2 (Design) Artwork |
Auditor Inspection | ||
PART 3 (Design) Spatial Familiarity |
Auditor Inspection |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Protocol) Charitable Activities |
Policy Document | ||
PART 2 (Design) Indoor Biophilia |
Architect | Spot Check | |
PART 3 (Design) Water Feature |
Architect | Spot Check |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Protocol) Innovation 2 Proposal |
Innovation Proposal | ||
PART 2 (Protocol) Innovation 1 Support |
Innovation Proposal |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Protocol) WELL Building Standard® Guide |
Auditor Inspection |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Classroom Space Allocation |
Architect | ||
PART 2 (Design) Housing Cost Limits |
Policy Document | ||
PART 3 (Protocol) Affordability Period |
Policy Document |
Letters of Assurance | Annotated Documents | On-Site Checks | |
---|---|---|---|
PART 1 (Design) Pedestrian Amenities |
Architect | Spot Check |