Posted on: 20 Oct, 2017
Amendment: For Part 5b, remove: "Project develops a plan to upgrade current mercury-containing lamp". Add: _“Project does not install any lamps not compliant with the low-mercury limits specified in Appendix C, Table A5. Project develops a plan to upgrade any existing non-compliant lamps to low-mercury or mercury-free lamps.”
|
Posted on: 20 Oct, 2017
Amendment: For Part 1c, add: "For door hardware, project teams must document attempt to meet the requirement and demonstrate a petition or a formal request has been filed with manufacturers who were unable to meet their needs." after "Not more than 100 ppm (by weight) added lead in all other building materials."
|
Posted on: 20 Oct, 2017
Amendment: In part description, remove: "following guidelines". Add: "below guidelines, and a policy is put in place for future work"
|
Posted on: 20 Oct, 2017
Amendment: For Part 3a, remove: "or by a U.S. EPA accredited company experienced in asbestos assessment". Add: "or" before "accredited asbestos consultant..."
|
Posted on: 27 Apr, 2017
Amendment: Remove: "Not more than 100 ppm (by weight) added lead". Add: "Not more than a weighted average of 0.25% lead in wetted surfaces of pipes, pipe fittings, plumbing fittings, and fixtures, and 0.20% for solder or flux used in plumbing for water intended for human consumption"
|
Posted on: 27 Apr, 2017
Amendment: Add "c. Not more than 100 ppm (by weight) added lead in all other building materials."
|