WELL Addenda
WELL ADDENDA
Review the complete list of addenda changes made to the WELL Building Standard.
Type | Description | Post Date |
---|---|---|
Intent |
Type: Intent
Post Date: 24 Oct, 2016 In the Feature description, remove the second paragraph. Replace with the following text: |
24 Oct, 2016 |
Type | Description | Post Date |
---|---|---|
Equivalency |
Type: Equivalency
Post Date: 06 Sep, 2018 The Japanese Agricultural Standards (JAS) organic system has been accepted as an equivalent for the Federally Certified Organic program of Feature 49 Part 1a and 2b for projects in Japan. |
06 Sep, 2018 |
Equivalency |
Type: Equivalency
Post Date: 29 May, 2018 The European Union Organic Logo has been accepted as an alternative for the Federally Certified Organic labeling requirements of Feature 49 Part 1 and 2. |
29 May, 2018 |
Equivalency |
Type: Equivalency
Post Date: 29 May, 2018 Organizations approved by the Australian Department of Agriculture as organic certifying organizations against the National Standard for Organic and Bio-Dynamic Produce are accepted as an equivalent for the Federally Certified Organic program of Feature 49 Part 1a and 2b. |
29 May, 2018 |
Equivalency |
Type: Equivalency
Post Date: 20 Mar, 2018 Soil Association Organic Standards Farming and Growing v17.4 August 2016 has been accepted as an alternative to Federally Certified Organic for the requirements of Feature 49, Part 2. Note that this equivalency applies only to projects in the United Kingdom. |
20 Mar, 2018 |
Equivalency |
Type: Equivalency
Post Date: 20 Mar, 2018 Scoring a 3 out of 3 in accordance with the "Beter Life" label (Beter Leven keurmerk) has been accepted as an alternative for the Certified Human Labeling requirements of Feature 49 - Responsible Food Production, Part 2. |
20 Mar, 2018 |
Amendment |
Type: Amendment
Post Date: 20 Oct, 2017 For Part 2a, remove: "Humane Certified". Add: "Certified Humane" |
20 Oct, 2017 |
Equivalency |
Type: Equivalency
Post Date: 21 Aug, 2017 "India Organic" certification by the APEDA (Agricultural and Processed Products Export Development Authority) per the National Programme for Organic Production (NPOP) standards has been accepted as an alternative for the requirements of Feature 49 Part 1. |
21 Aug, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "Produce is sold or distributed on the premises on a daily basis by (or under contract with) the project owner and it meets the following criteria". Add: "Produce is sold or provided on the premises on a daily basis by (or under contract with) the project owner that meets the following criteria" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "(based on country) |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "If meat, egg or dairy products are sold or distributed on the premises on a daily basis by (or under contract with) the project owner, they meet the following criteria for the humane treatment of livestock". Add: ""If meat, egg or dairy products are sold or provided on the premises on a daily basis by (or under contract with) the project owner, they meet the following criteria for the humane treatment of livestock" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove:"(based on the country)". Add: "or equivalent" |
27 Apr, 2017 |
Intent |
Type: Intent
Post Date: 24 Oct, 2016 In the Feature description, remove the second paragraph. Replace with the following text: |
24 Oct, 2016 |
Amendment |
Type: Amendment
Post Date: 06 May, 2016 Change “All produce sold or distributed on the premises on a daily basis by (or under contract with) the project owner meets the following criteria:” to “Produce is sold or distributed on the premises on a daily basis by (or under contract with) the project owner and it meets the following criteria:” |
06 May, 2016 |
Amendment |
Type: Amendment
Post Date: 06 May, 2016 Change “All meat egg and dairy products sold or distributed on the premises on a daily basis by (or under contract with) the project owner meet the following criteria…” to “If meat, egg or dairy products are sold or distributed on the premises on a daily basis by (or under contract with) the project owner, they meet the following criteria…” |
06 May, 2016 |
Type | Description | Post Date |
---|---|---|
Amendment |
Type: Amendment
Post Date: 20 Oct, 2017 Add: "one of" before "the following" |
20 Oct, 2017 |
Amendment |
Type: Amendment
Post Date: 20 Oct, 2017 Add: "b. Evidence that the volume provided exceeds occupant demand by at least 20%." |
20 Oct, 2017 |
Intent |
Type: Intent
Post Date: 24 Oct, 2016 In the Feature description, remove the second paragraph. Replace with the following text: |
24 Oct, 2016 |
Verification type |
Type: Verification type
Post Date: 10 Feb, 2016 Add Owner Letter of Assurance as required documentation, remove Architect Letter of Assurance. |
10 Feb, 2016 |
Type | Description | Post Date |
---|---|---|
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove:"allocated". Add: "accessible and located" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Add: "with food-bearing plants" after "A garden" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Add: "with food-bearing plants" after "A greenhouse" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Add: "c. Edible landscaping (e.g., fruit trees, herbs)." |
27 Apr, 2017 |
Intent |
Type: Intent
Post Date: 24 Oct, 2016 In the Feature description, remove the second paragraph. Replace with the following text: |
24 Oct, 2016 |
Verification type |
Type: Verification type
Post Date: 10 Feb, 2016 Add Owner Letters of Assurance as required documentation, remove Architect Letter of Assurance. |
10 Feb, 2016 |
Type | Description | Post Date |
---|---|---|
Amendment |
Type: Amendment
Post Date: 05 Feb, 2018 In part description, remove: "early education, elementary, middle, and high schools". Add: "early education, primary and secondary schools" |
05 Feb, 2018 |
Amendment |
Type: Amendment
Post Date: 20 Oct, 2017 In Appendix I, remove: "Extent of Developer Buildout with Capacity for Tenant Achievement". Add: "Entire Building" |
20 Oct, 2017 |
Amendment |
Type: Amendment
Post Date: 26 Jul, 2017 In part description, Remove: "employees". Add: "occupants" |
26 Jul, 2017 |
Amendment |
Type: Amendment
Post Date: 26 Jul, 2017 In Part 1 and Part 2, remove: "employees". Add: "occupants" |
26 Jul, 2017 |
Amendment |
Type: Amendment
Post Date: 26 Jul, 2017 Remove: "employees". Add: "occupants" |
26 Jul, 2017 |
Amendment |
Type: Amendment
Post Date: 26 Jul, 2017 In part description, Remove: "employees". Add: "occupants" |
26 Jul, 2017 |
Amendment |
Type: Amendment
Post Date: 26 Jul, 2017 Remove: "employee". Add: "occupant" |
26 Jul, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "b. Are located within 60 m [200 ft] of at least 90% of all occupants" |
27 Apr, 2017 |
Intent |
Type: Intent
Post Date: 24 Oct, 2016 In the Feature description, remove the second paragraph. Replace with the following text: |
24 Oct, 2016 |
Amendment |
Type: Amendment
Post Date: 06 May, 2016 In Part 2a, change “Refrigerator, microwave and sink” to “Refrigerator, device for reheating food (such as microwave or toaster oven) and sink” |
06 May, 2016 |
Type | Description | Post Date |
---|---|---|
Amendment |
Type: Amendment
Post Date: 01 May, 2019 If average ambient light is below 300 lux [28 fc] and meets Part 1a, task lights providing 300 to 500 lux [28 to 46 fc] at the work surface are available upon request. |
01 May, 2019 |
Amendment |
Type: Amendment
Post Date: 15 Aug, 2018 In 17 Jan, 2017 EP, remove: "Note that this...China GB50034-2013 to ensure compliance." |
15 Aug, 2018 |
Amendment |
Type: Amendment
Post Date: 07 Jun, 2018 For Part 5a, remove: "elementary, middle and high schools". Add: "primary and secondary schools" |
07 Jun, 2018 |
Amendment |
Type: Amendment
Post Date: 07 Jun, 2018 For Part 1c, add "average" before "ambient light" |
07 Jun, 2018 |
Amendment |
Type: Amendment
Post Date: 07 Jun, 2018 For Part 1a, remove: "plane, 0.76 m [30 inches] above finished floor". Add: "work plane" |
07 Jun, 2018 |
Alternative Adherence Path |
Type: Alternative Adherence Path
Post Date: 05 Feb, 2018 Projects may meet requirements outlined in Part 1b by zoning the space into banks according to proximity to windows or corresponding to location of departments even if the areas differ from those prescribed in Part 1b. |
05 Feb, 2018 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "Brightness contract between main rooms and ancillary spaces, such as corridors and stairwells, if present". Add: "Maximum brightness contrasts between main rooms and ancillary spaces, such as corridors and stairwells, if present. For example, projects may establish that, while still maintaining lighting variety, a main room cannot exhibit 10 times greater or lesser luminance than an ancillary space" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "Brightness contrasts between task surfaces and immediately adjacent surfaces, including adjacent visual display terminal screens". Add: "Maximum brightness contrasts between task surfaces and immediately adjacent surfaces, including adjacent visual display terminal screens. For example, projects may establish that, while still maintaining lighting variety, a surface cannot exhibit 3 times greater or lesser luminance than an adjacent surface" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "Brightness contrasts between task surfaces and remote, non-adjacent surfaces in the same room". Add: "Brightness contrasts between task surfaces and remote, non-adjacent surfaces in the same room. For example, projects may establish that, while still maintaining lighting variety, a surface cannot exhibit 10 times greater or lesser luminance than another remote surface in the same room" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "The way brightness is distributed across ceilings in a given room". Add: "The way brightness is distributed across ceilings in a given room that maintains lighting variety but avoids both dark spots, or excessively bright, potentially glaring spots. For example, projects may establish that, while still maintaining lighting variety, one part of the ceiling cannot be 10 times greater or lesser luminance than another part of the ceiling in the same room" |
27 Apr, 2017 |
Equivalency |
Type: Equivalency
Post Date: 17 Jan, 2017 The China standard GB50034-2013 has been approved to meet the requirements of Feature 53 Part 1a. |
17 Jan, 2017 |
Verification type |
Type: Verification type
Post Date: 24 Oct, 2016 For Feature 53, Part 1 add Policy Document as required documentation, along with Architect Letter of Assurance and Spot Measurement. This policy document should be used to confirm the requirements of Part 1c of this feature. |
24 Oct, 2016 |
Intent |
Type: Intent
Post Date: 24 Oct, 2016 In the Feature description, remove the second paragraph. Replace with the following text: |
24 Oct, 2016 |
Verification type |
Type: Verification type
Post Date: 10 Feb, 2016 Add professional narrative as required documentation, remove Architect Letter of Assurance, remove on-site spot measurements. |
10 Feb, 2016 |
Type | Description | Post Date |
---|---|---|
Amendment |
Type: Amendment
Post Date: 01 Nov, 2018 For Part 2b, remove: "Lights" before "provide not more than…". Add: "During the nighttime, lights" |
01 Nov, 2018 |
Amendment |
Type: Amendment
Post Date: 07 Jun, 2018 For Part 4a, remove: "elementary, middle and high schools". Add: "primary and secondary schools" |
07 Jun, 2018 |
Amendment |
Type: Amendment
Post Date: 07 Jun, 2018 For Part 4b, remove: "elementary school, middle school, or high school". Add: "primary and secondary school" |
07 Jun, 2018 |
Amendment |
Type: Amendment
Post Date: 05 Feb, 2018 In 17 Jan, 2017 AAP, remove: "task". Add: "task or other supplemental lighting" |
05 Feb, 2018 |
Amendment |
Type: Amendment
Post Date: 05 Feb, 2018 For Part 1b, remove: "(which may include task lighting)" after "electric lights" |
05 Feb, 2018 |
Amendment |
Type: Amendment
Post Date: 20 Oct, 2017 For Part 1b, remove: "Vertical (Ev) Targets for the 25-65 category in Table B1 of IES-ANSI RP-1-12". Add: "required amount" |
20 Oct, 2017 |
Amendment |
Type: Amendment
Post Date: 26 Jul, 2017 For Part 1b, add: "facing forward (to simulate the view of the occupant)" after "vertical plane" |
26 Jul, 2017 |
Amendment |
Type: Amendment
Post Date: 26 Jul, 2017 Add: "During Performance Verification, EML is measured on the vertical plane at eye level of the occupant." after "The biological effects of light on humans can be measured in Equivalent Melanopic Lux (EML), a proposed alternate metric that is weighted to the ipRGCs instead of to the cones, which is the case with traditional lux." |
26 Jul, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "At least one of the following requirements is met". Add: " Light models or light calculations demonstrate that at least one of the following requirements is met" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "Light models or light calculations (which may incorporate daylight) show that at least 250 equivalent melanopic lux is present at 75% or more of workstations, measured on the vertical plane facing forward, 1.2 m [4 ft] above finished floor (to stimulate the view of the occupant). This light level is present for at least 4 hours per day for every day of the year". Add: "At 75% or more of workstations, at least 200 equivalent melanopic lux is present, measured on the vertical plane facing forward, 1.2 m [4 ft] above finished floor (to simulate the view of the occupant). This light level may incorporate daylight, and is present for at least the hours between 9:00 AM and 1:00 PM for every day of the year" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: " For all workstations, electric lights (which may include task lighting) provide maintained illuminance on the vertical plane of equivalent melanopic lux, greater than or equal to the lux recommendations in the Vertical (Ev) Targets for the 25-65 category in Table B1 of IES-ANSI RP-1-12. For example, Reception Desks are provided with 150 equivalent melanopic lux from the electric lights". Add: "For all workstations, electric lights (which may include task lighting) provide maintained illuminance on the vertical plane of 150 equivalent melanopic lux or greater. Projects may use the lux recommendations in the Vertical (Ev) Targets for the 25-65 category in Table B1 of IES-ANSI RP-1-12 in place of 150" |
27 Apr, 2017 |
Alternative Adherence Path |
Type: Alternative Adherence Path
Post Date: 27 Apr, 2017 Projects pursuing option a, in place of a letter of assurance and on-site spot checks as indicated in the Performance Verification Guidebook, may provide an annotated floor plan which identifies a subset of workstations that comprise at least 75% of the total number present on site. During Performance Verification, the WELL Performance Testing Agent will restrict sampling to these workstations, and compliance with this feature will be based on 100% of samples equaling or exceeding 200 equivalent melanopic lux. |
27 Apr, 2017 |
Alternative Adherence Path |
Type: Alternative Adherence Path
Post Date: 17 Jan, 2017 To increase the delivered Equivalent Melanopic Lux and fulfill Feature 54, projects may provide task or other supplemental lighting at workstations upon request. Projects choosing to pursue this option must demonstrate that they have sufficient funding to procure task or other supplemental lighting for at least 75% of the total workstations within the WELL boundary. Projects must also provide comprehensive education to employees that focuses on the benefits of task or other supplemental lighting and circadian lighting overall. |
17 Jan, 2017 |
Intent |
Type: Intent
Post Date: 24 Oct, 2016 In the Feature description, remove the second paragraph. Replace with the following text: |
24 Oct, 2016 |
Amendment |
Type: Amendment
Post Date: 06 May, 2016 In Part 1b, change “For all workstations, electric lights provide…” to “For all workstations, electric lights (which may include task lighting) provide…” |
06 May, 2016 |
Amendment |
Type: Amendment
Post Date: 10 Feb, 2016 In Part 1b, Change first part of first sentence from “Electric lights provide” to "For all workstations, electric lights provide" |
10 Feb, 2016 |
Type | Description | Post Date |
---|---|---|
Amendment |
Type: Amendment
Post Date: 01 May, 2019 At workstations, desks, and other seating areas in regularly occupied spaces, one of the following requirements |
01 May, 2019 |
Type | Description | Post Date |
---|---|---|
Amendment |
Type: Amendment
Post Date: 01 Nov, 2018 For Part 2b, add ", desks and other seating areas" after "Workstations" |
01 Nov, 2018 |
Amendment |
Type: Amendment
Post Date: 07 Jun, 2018 For Part 2, remove: "requirement". Add: "requirements" |
07 Jun, 2018 |
Amendment |
Type: Amendment
Post Date: 07 Jun, 2018 For Part 2, add: "one of the" after "...and other seating areas," |
07 Jun, 2018 |
Amendment |
Type: Amendment
Post Date: 07 Jun, 2018 For Part 2, add: "b. Workstations achieve a UGR of 19 (or less)." |
07 Jun, 2018 |
Amendment |
Type: Amendment
Post Date: 26 Jul, 2017 In part heading, Remove: "Lamp". Add: "Luminaire" |
26 Jul, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "50,000 to 500,000 cd/m²: 20°". Add: "⍺: 20° for 50,000 to 500,000 cd/m²" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "20,000 to 50,000 cd/m²: 15°". Add: "⍺: 15° for 20,000 to 50,000 cd/m²" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "500,000 cd/m² and above: 30°". Add: "⍺: 30° for 500,000 cd/m² and above" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "Bare lamps and luminaire surfaces". Add: "Luminaires" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "Lamps with the following luminance in regularly occupied spaces are shielded by the angles listed below or greater". Add: "The following shielding angles (⍺ = 90 - cutoff angle) must be observed for lamps in regularly occupied spaces with luminance values in the ranges specified" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "Less than 20,000 cd/m², including reflected sources: no shielding required". Add: "No shielding required for less than 20,000 cd/m² (including reflected sources)" |
27 Apr, 2017 |
Equivalency |
Type: Equivalency
Post Date: 24 Oct, 2016 The Unified Glare Rating (UGR) value may be used in lieu of the requirements of Feature 55 as written. Specifically, the recommendations in EN 12464-1 may be used in place of Part 1. |
24 Oct, 2016 |
Intent |
Type: Intent
Post Date: 24 Oct, 2016 In the Feature description, remove the second paragraph. Replace with the following text: |
24 Oct, 2016 |
Amendment |
Type: Amendment
Post Date: 06 May, 2016 Change “At workstations and desks, the following requirement is met:” to “At workstations, desks and other seating areas, the following requirement is met:” |
06 May, 2016 |
Type | Description | Post Date |
---|---|---|
Amendment |
Type: Amendment
Post Date: 07 Jun, 2018 In part description, add: "(excluding lobbies)" after "regularly occupied spaces" |
07 Jun, 2018 |
Intent |
Type: Intent
Post Date: 24 Oct, 2016 In the Feature description, remove the second paragraph. Replace with the following text: |
24 Oct, 2016 |
Alternative Adherence Path |
Type: Alternative Adherence Path
Post Date: 24 Oct, 2016 The following glare control strategies may be used in lieu of glare requirements for atriums. Project teams may submit a plan or narrative detailing the use of a combination of the following: glare reducing film that has a solar transmittance of 10% or less, space planning to ensure workstations are set back from atrium spaces by at least 7 feet, and building orientation to reduce solar glare. Project teams must demonstrate that occupant comfort is not impacted. |
24 Oct, 2016 |
Amendment |
Type: Amendment
Post Date: 06 May, 2016 In Part 1a, change “Interior window shading or blinds that are controllable by the occupants or set on a timer” to “Interior window shading or blinds that are controllable by the occupants or set to automatically prevent glare.” |
06 May, 2016 |
Amendment |
Type: Amendment
Post Date: 06 May, 2016 In Part 1b, change “External shading systems that are controllable by the occupants or set on a timer” to “External shading systems that are set to automatically prevent glare” |
06 May, 2016 |
Amendment |
Type: Amendment
Post Date: 06 May, 2016 Change “At least one of the following is required for all glazing greater than 2.1 m (7 ft) above the floor:” to “At least one of the following is required for all glazing greater than 2.1 m (7 ft) above the floor in regularly occupied spaces:” |
06 May, 2016 |
Amendment |
Type: Amendment
Post Date: 06 May, 2016 In Part 2a, change “Interior window shading or blinds that are controllable by the occupants or set on a timer” to “Interior window shading or blinds that are controllable by the occupants or set to automatically prevent glare.” |
06 May, 2016 |
Amendment |
Type: Amendment
Post Date: 06 May, 2016 In Part 2b, change “External shading systems that are controllable by the occupants or set on a timer.” To “External shading systems that are set to automatically prevent glare.” |
06 May, 2016 |
Amendment |
Type: Amendment
Post Date: 06 May, 2016 Change “At least one of the following is present for all glazing less than 2.1m [7 ft] above the floor:” to “At least one of the following is present for all glazing less than 2.1m [7 ft] above the floor in regularly occupied spaces:” |
06 May, 2016 |
Type | Description | Post Date |
---|---|---|
Intent |
Type: Intent
Post Date: 24 Oct, 2016 In the Feature description, remove the second paragraph. Replace with the following text: |
24 Oct, 2016 |
Alternative Adherence Path |
Type: Alternative Adherence Path
Post Date: 06 May, 2016 Monitors with adjustable monitor arms that allow the occupant to move the computer screens to face within a 20 degree perpendicular to the plane of the nearest window may be used to meet the requirements of Part 1a (Glare Avoidance). |
06 May, 2016 |
Alternative Adherence Path |
Type: Alternative Adherence Path
Post Date: 06 May, 2016 Inquiry: Can “free address” workstations, allowing occupants to change workstations to avoid glare, be used to meet the feature requirements? Ruling: No, free address workstations may not be used to meet the feature requirements. |
06 May, 2016 |
Amendment |
Type: Amendment
Post Date: 10 Feb, 2016 In Part 1a, change the first part of the first sentence from “To minimize glare cause by incoming sunlight, all computer screens for at desks” to "To minimize glare caused by incoming sunlight, all computer screens at desks" |
10 Feb, 2016 |
Type | Description | Post Date |
---|---|---|
Amendment |
Type: Amendment
Post Date: 01 May, 2019 To accurately portray colors in the space and enhance occupant comfort, all electric lights in occupiable spaces (except decorative fixtures, emergency lights and other special-purpose lighting) meet the following conditions: |
01 May, 2019 |
Amendment |
Type: Amendment
Post Date: 07 Jun, 2018 In 20 Oct, 2017 AAP, remove: "regularly occupied". Add: "all other" |
07 Jun, 2018 |
Alternative Adherence Path |
Type: Alternative Adherence Path
Post Date: 20 Oct, 2017 In transient areas, light sources with CRI of 80 and R9 of 15 may be used. Light sources used in regularly occupied areas must meet the requirements of Feature 58 as written. |
20 Oct, 2017 |
Intent |
Type: Intent
Post Date: 24 Oct, 2016 In the Feature description, remove the second paragraph. Replace with the following text: |
24 Oct, 2016 |
Type | Description | Post Date |
---|---|---|
Alternative Adherence Path |
Type: Alternative Adherence Path
Post Date: 01 May, 2019 Multi-Family Residential projects may achieve Feature 59 Part 2 and 3 by providing multi-level dimmable lighting for all ambient lighting in bedrooms and living areas. In addition, shades must be provided in both the bedroom and living areas, as follows: |
01 May, 2019 |
Amendment |
Type: Amendment
Post Date: 05 Feb, 2018 For Part 1b, remove: "Walls". Add: "Vertical surfaces" |
05 Feb, 2018 |
Intent |
Type: Intent
Post Date: 24 Oct, 2016 In the Feature description, remove the second paragraph. Replace with the following text: |
24 Oct, 2016 |