Displacement ventilation
- 1 Air quality standards
- 2 Smoking ban
- 3 Ventilation effectiveness
- 4 VOC reduction
- 5 Air filtration
- 6 Microbe and mold control
- 7 Construction pollution management
- 8 Healthy entrance
- 9 Cleaning protocol
- 10 Pesticide management
- 11 Fundamental material safety
- 12 Moisture management
- 13 Air flush
- 14 Air infiltration management
- 15 Increased ventilation
- 16 Humidity control
- 17 Direct source ventilation
- 18 Air quality monitoring and feedback
- 19 Operable windows
- 20 Outdoor air systems
- 21 Displacement ventilation
- 22 Pest control
- 23 Advanced air purification
- 24 Combustion minimization
- 25 Toxic material reduction
- 26 Enhanced material safety
- 27 Antimicrobial surfaces
- 28 Cleanable environment
- 29 Cleaning equipment
21. Displacement ventilation
By providing ventilation at the normal breathing zone displacement ventilation enhances air change effectiveness. Since heat in a room is naturally stratified, displacement ventilation ensures that air is not delivered and pushed through the return air path (often the dirtiest portion of the air stream) and also tends to concentrate some pollutants near the ceiling. Once there, the pollutants are out of the breathing zone and more easily removed. Displacement ventilation supplies air at very low velocity levels at or near floor level. Air then rises and returns at the ceiling level.
This feature supports a thermally comfortable indoor environment through a carefully designed and efficient displacement ventilation system.
One of the following is met for projects implementing a displacement ventilation system for heating and/or cooling:
The following requirements are met:

Applicability Matrix
| Core & Shell | New Construction | WELL Interiors | |
|---|---|---|---|
| Part 1: Displacement Ventilation Design and Application | - | O | O |
| Part 2: System Performance | - | O | O |
| Commercial Kitchen | Education | Multifamily Residential | Retail | |
|---|---|---|---|---|
| Part 1: Displacement Ventilation Design and Application | - | - | O | O |
| Part 2: System Performance | - | - | O | O |
| 21.1.b |
ASHRAE's Underfloor Air Distribution Guide provides recommendations for underfloor air distribution systems. |
| 21.1.a |
The Performance Evaluation and Development of Design Guidelines for Displacement Ventilation document recommends air supply temperatures. |
| 21.2.b |
ASHRAE Standard 55 provides guidelines for displacement ventilation systems for thermal environmental comfort. |