Type | Description | Post Date |
---|---|---|
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "The way brightness is distributed across ceilings in a given room". Add: "The way brightness is distributed across ceilings in a given room that maintains lighting variety but avoids both dark spots, or excessively bright, potentially glaring spots. For example, projects may establish that, while still maintaining lighting variety, one part of the ceiling cannot be 10 times greater or lesser luminance than another part of the ceiling in the same room" |
27 Apr, 2017 |
Equivalency |
Type: Equivalency
Post Date: 17 Jan, 2017 The China standard GB50024-2013 has been approved to meet the requirements of Feature 53 Part 1a. |
17 Jan, 2017 |
Intent |
Type: Intent
Post Date: 24 Oct, 2016 In the Feature description, remove the second paragraph. Replace with the following text: |
24 Oct, 2016 |
Verification type |
Type: Verification type
Post Date: 24 Oct, 2016 For Feature 53, Part 1 add Policy Document as required documentation, along with Architect Letter of Assurance and Spot Measurement. This policy document should be used to confirm the requirements of Part 1c of this feature. |
24 Oct, 2016 |
Verification type |
Type: Verification type
Post Date: 10 Feb, 2016 Add professional narrative as required documentation, remove Architect Letter of Assurance, remove on-site spot measurements. |
10 Feb, 2016 |
Type | Description | Post Date |
---|---|---|
Amendment |
Type: Amendment
Post Date: 26 Jul, 2017 Add: "During Performance Verification, EML is measured on the vertical plane at eye level of the occupant." after "The biological effects of light on humans can be measured in Equivalent Melanopic Lux (EML), a proposed alternate metric that is weighted to the ipRGCs instead of to the cones, which is the case with traditional lux." |
26 Jul, 2017 |
Amendment |
Type: Amendment
Post Date: 26 Jul, 2017 For Part 1b, add: "facing forward (to simulate the view of the occupant)" after "vertical plane" |
26 Jul, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "At least one of the following requirements is met". Add: " Light models or light calculations demonstrate that at least one of the following requirements is met" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "Light models or light calculations (which may incorporate daylight) show that at least 250 equivalent melanopic lux is present at 75% or more of workstations, measured on the vertical plane facing forward, 1.2 m [4 ft] above finished floor (to stimulate the view of the occupant). This light level is present for at least 4 hours per day for every day of the year". Add: "At 75% or more of workstations, at least 200 equivalent melanopic lux is present, measured on the vertical plane facing forward, 1.2 m [4 ft] above finished floor (to simulate the view of the occupant). This light level may incorporate daylight, and is present for at least the hours between 9:00 AM and 1:00 PM for every day of the year" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: " For all workstations, electric lights (which may include task lighting) provide maintained illuminance on the vertical plane of equivalent melanopic lux, greater than or equal to the lux recommendations in the Vertical (Ev) Targets for the 25-65 category in Table B1 of IES-ANSI RP-1-12. For example, Reception Desks are provided with 150 equivalent melanopic lux from the electric lights". Add: "For all workstations, electric lights (which may include task lighting) provide maintained illuminance on the vertical plane of 150 equivalent melanopic lux or greater. Projects may use the lux recommendations in the Vertical (Ev) Targets for the 25-65 category in Table B1 of IES-ANSI RP-1-12 in place of 150" |
27 Apr, 2017 |
Alternative Adherence Path |
Type: Alternative Adherence Path
Post Date: 27 Apr, 2017 Projects pursuing option a, in place of a letter of assurance and on-site spot checks as indicated in the Performance Verification Guidebook, may provide an annotated floor plan which identifies a subset of workstations that comprise at least 75% of the total number present on site. During Performance Verification, the WELL Assessor will restrict sampling to these workstations, and compliance with this feature will be based on 100% of samples equaling or exceeding 200 equivalent melanopic lux. |
27 Apr, 2017 |
Alternative Adherence Path |
Type: Alternative Adherence Path
Post Date: 17 Jan, 2017 To increase the delivered Equivalent Melanopic Lux and fulfill Feature 54, projects may provide task lighting at workstations upon request. Projects choosing to pursue this option must demonstrate that they have sufficient funding to procure task lighting for at least 75% of the total workstations within the WELL boundary. Projects must also provide comprehensive education to employees that focuses on the benefits of task lighting and circadian lighting overall. |
17 Jan, 2017 |
Intent |
Type: Intent
Post Date: 24 Oct, 2016 In the Feature description, remove the second paragraph. Replace with the following text: |
24 Oct, 2016 |
Amendment |
Type: Amendment
Post Date: 06 May, 2016 In Part 1b, change “For all workstations, electric lights provide…” to “For all workstations, electric lights (which may include task lighting) provide…” |
06 May, 2016 |
Amendment |
Type: Amendment
Post Date: 10 Feb, 2016 In Part 1b, Change first part of first sentence from “Electric lights provide” to "For all workstations, electric lights provide" |
10 Feb, 2016 |
Type | Description | Post Date |
---|---|---|
Amendment |
Type: Amendment
Post Date: 26 Jul, 2017 In part heading, Remove: "Lamp". Add: "Luminaire" |
26 Jul, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "20,000 to 50,000 cd/m²: 15°". Add: "⍺: 15° for 20,000 to 50,000 cd/m²" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "500,000 cd/m² and above: 30°". Add: "⍺: 30° for 500,000 cd/m² and above" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "Bare lamps and luminaire surfaces". Add: "Luminaires" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "Lamps with the following luminance in regularly occupied spaces are shielded by the angles listed below or greater". Add: "The following shielding angles (⍺ = 90 - cutoff angle) must be observed for lamps in regularly occupied spaces with luminance values in the ranges specified" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "Less than 20,000 cd/m², including reflected sources: no shielding required". Add: "No shielding required for less than 20,000 cd/m² (including reflected sources)" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "50,000 to 500,000 cd/m²: 20°". Add: "⍺: 20° for 50,000 to 500,000 cd/m²" |
27 Apr, 2017 |
Equivalency |
Type: Equivalency
Post Date: 24 Oct, 2016 The Unified Glare Rating (UGR) value may be used in lieu of the requirements of Feature 55 as written. Specifically, the recommendations in EN 12464-1 may be used in place of Part 1. For Part 2, workstations should have a UGR of 19 (or less). |
24 Oct, 2016 |
Intent |
Type: Intent
Post Date: 24 Oct, 2016 In the Feature description, remove the second paragraph. Replace with the following text: |
24 Oct, 2016 |
Amendment |
Type: Amendment
Post Date: 06 May, 2016 Change “At workstations and desks, the following requirement is met:” to “At workstations, desks and other seating areas, the following requirement is met:” |
06 May, 2016 |
Type | Description | Post Date |
---|---|---|
Alternative Adherence Path |
Type: Alternative Adherence Path
Post Date: 24 Oct, 2016 The following glare control strategies may be used in lieu of glare requirements for atriums. Project teams may submit a plan or narrative detailing the use of a combination of the following: glare reducing film that has a solar transmittance of 10% or less, space planning to ensure workstations are set back from atrium spaces by at least 7 feet, and building orientation to reduce solar glare. Project teams must demonstrate that occupant comfort is not impacted. |
24 Oct, 2016 |
Equivalency |
Type: Equivalency
Post Date: 24 Oct, 2016 Green Star Credit 12.0: Glare Reduction is an accepted equivalent for Feature 56. Compliance with the Green Star Credit requirements is sufficient to comply with the WELL feature. |
24 Oct, 2016 |
Intent |
Type: Intent
Post Date: 24 Oct, 2016 In the Feature description, remove the second paragraph. Replace with the following text: |
24 Oct, 2016 |
Amendment |
Type: Amendment
Post Date: 06 May, 2016 Change “At least one of the following is present for all glazing less than 2.1m [7 ft] above the floor:” to “At least one of the following is present for all glazing less than 2.1m [7 ft] above the floor in regularly occupied spaces:” |
06 May, 2016 |
Amendment |
Type: Amendment
Post Date: 06 May, 2016 In Part 1a, change “Interior window shading or blinds that are controllable by the occupants or set on a timer” to “Interior window shading or blinds that are controllable by the occupants or set to automatically prevent glare.” |
06 May, 2016 |
Amendment |
Type: Amendment
Post Date: 06 May, 2016 In Part 1b, change “External shading systems that are controllable by the occupants or set on a timer” to “External shading systems that are set to automatically prevent glare” |
06 May, 2016 |
Amendment |
Type: Amendment
Post Date: 06 May, 2016 Change “At least one of the following is required for all glazing greater than 2.1 m (7 ft) above the floor:” to “At least one of the following is required for all glazing greater than 2.1 m (7 ft) above the floor in regularly occupied spaces:” |
06 May, 2016 |
Amendment |
Type: Amendment
Post Date: 06 May, 2016 In Part 2a, change “Interior window shading or blinds that are controllable by the occupants or set on a timer” to “Interior window shading or blinds that are controllable by the occupants or set to automatically prevent glare.” |
06 May, 2016 |
Amendment |
Type: Amendment
Post Date: 06 May, 2016 In Part 2b, change “External shading systems that are controllable by the occupants or set on a timer.” To “External shading systems that are set to automatically prevent glare.” |
06 May, 2016 |
Type | Description | Post Date |
---|---|---|
Intent |
Type: Intent
Post Date: 24 Oct, 2016 In the Feature description, remove the second paragraph. Replace with the following text: |
24 Oct, 2016 |
Alternative Adherence Path |
Type: Alternative Adherence Path
Post Date: 06 May, 2016 Monitors with adjustable monitor arms that allow the occupant to move the computer screens to face within a 20 degree perpendicular to the plane of the nearest window may be used to meet the requirements of Part 1a (Glare Avoidance). |
06 May, 2016 |
Alternative Adherence Path |
Type: Alternative Adherence Path
Post Date: 06 May, 2016 Inquiry: Can “free address” workstations, allowing occupants to change workstations to avoid glare, be used to meet the feature requirements? Ruling: No, free address workstations may not be used to meet the feature requirements. |
06 May, 2016 |
Amendment |
Type: Amendment
Post Date: 10 Feb, 2016 In Part 1a, change the first part of the first sentence from “To minimize glare cause by incoming sunlight, all computer screens for at desks” to "To minimize glare caused by incoming sunlight, all computer screens at desks" |
10 Feb, 2016 |
Type | Description | Post Date |
---|---|---|
Intent |
Type: Intent
Post Date: 24 Oct, 2016 In the Feature description, remove the second paragraph. Replace with the following text: |
24 Oct, 2016 |
Type | Description | Post Date |
---|---|---|
Intent |
Type: Intent
Post Date: 24 Oct, 2016 In the Feature description, remove the second paragraph. Replace with the following text: |
24 Oct, 2016 |
Type | Description | Post Date |
---|---|---|
Intent |
Type: Intent
Post Date: 24 Oct, 2016 In the Feature description, remove the second paragraph. Replace with the following text: |
24 Oct, 2016 |
Amendment |
Type: Amendment
Post Date: 06 May, 2016 In Part 1a, change “Shading devices that automatically engage when light sensors indicate that sunlight could contribute to glare at workstations” to “Shading devices that automatically engage when light sensors indicate that sunlight could contribute to glare at workstations and other seating areas.” |
06 May, 2016 |
Verification type |
Type: Verification type
Post Date: 10 Feb, 2016 Add MEP Letters of Assurance as required documentation, remove Architect Letters of Assurance. |
10 Feb, 2016 |
Type | Description | Post Date |
---|---|---|
Intent |
Type: Intent
Post Date: 24 Oct, 2016 In the Feature description, remove the second paragraph. Replace with the following text: |
24 Oct, 2016 |
Alternative Adherence Path |
Type: Alternative Adherence Path
Post Date: 06 May, 2016 Inquiry: Can a daylighting analysis confirming that at least 90% of regularly occupied spaces have sufficient daylight illumination levels (at least 30 footcandles) and that 100% of spaces have access to quality outdoor views be used to meet the feature requirements? Ruling: No, a daylighting simulation combined with access to quality views may not be utilized to meet the feature requirements. The intent of Feature 61 is to include proximity to windows, outdoor views, and daylight in indoor spaces. |
06 May, 2016 |
Amendment |
Type: Amendment
Post Date: 06 May, 2016 In Part 2a, change “75% of all desks or regularly occupied seats…” to “75% of all workstations…” |
06 May, 2016 |
Amendment |
Type: Amendment
Post Date: 06 May, 2016 In Part 2b, change “95% of all desks or regularly occupied seats…” to “95% of all workstations…” |
06 May, 2016 |
Type | Description | Post Date |
---|---|---|
Equivalency |
Type: Equivalency
Post Date: 17 Jan, 2017 BREEAM UK New Construction 2014, Credit Hea 01: Visual comfort, criteria 3a or 3b has been approved to comply with F62 of the Multifamily Residential Pilot. |
17 Jan, 2017 |
Alternative Adherence Path |
Type: Alternative Adherence Path
Post Date: 24 Oct, 2016 As an alternative to a lighting simulation to determine the sDA of the space, project teams may use the LEED v4 BD+C EQ Daylight Credit requirements to fulfil the requirement. The provided lighting analysis document must be updated to demonstrate that 90% of the regularly occupied floor area meets the requirements (i.e. 2 points under LEED v4 BD+C EQ Daylight credit). |
24 Oct, 2016 |
Equivalency |
Type: Equivalency
Post Date: 24 Oct, 2016 The Green Star Daylight criterion is deemed partially equivalent to the requirements of Feature 62. Compliance with the Green Star credit is sufficient to comply with Part 1a of the WELL feature. |
24 Oct, 2016 |
Intent |
Type: Intent
Post Date: 24 Oct, 2016 In the Feature description, remove the second paragraph. Replace with the following text: |
24 Oct, 2016 |
Alternative Adherence Path |
Type: Alternative Adherence Path
Post Date: 06 May, 2016 Inquiry: Can an automatic shading system that draws shades when sensors indicate that daylight can contribute to glare at workstations be used in lieu of meeting the feature requirements? Ruling: No, the installation of automated shading devices alone does not meet the feature requirements, as this feature requires demonstration that as a result of the overall lighting design, the project is able to achieve the proper amount of daylighting. |
06 May, 2016 |
Verification type |
Type: Verification type
Post Date: 10 Feb, 2016 Add annotated modeling report as required documentation, remove annotated architectural drawing. |
10 Feb, 2016 |
Type | Description | Post Date |
---|---|---|
Amendment |
Type: Amendment
Post Date: 26 Jul, 2017 For Part 1b, remove: "(Daylight Glass)", after "above the floor" |
26 Jul, 2017 |
Amendment |
Type: Amendment
Post Date: 26 Jul, 2017 For Part 2a, remove: "(Daylight Glass)", after "from the floor" |
26 Jul, 2017 |
Amendment |
Type: Amendment
Post Date: 26 Jul, 2017 For Part 2b, remove: "(Vision Glass)" after "from the floor" |
26 Jul, 2017 |
Intent |
Type: Intent
Post Date: 24 Oct, 2016 In the Feature description, remove the second paragraph. Replace with the following text: |
24 Oct, 2016 |
Amendment |
Type: Amendment
Post Date: 06 May, 2016 Change “The following conditions are met:” to “The following conditions are met on façades along regularly occupied spaces:” |
06 May, 2016 |
Type | Description | Post Date |
---|---|---|
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Add: "f. Biophilic elements" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Add: "AND PROMOTION" after "STAIR ACCESSIBILITY" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Add: "throughout the space" before "Wayfinding signage" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "STAIR PROMOTION" after "PART 2:". Add: " STAIRCASE DESIGN" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "entrance to the building or the edge of its lobby". Add: "building's main entrance, main entry check-point (e.g., welcome/reception desk), the edge of its main lobby, or edge of its main welcome area." |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "Clearly visible from the main entrance to the project, or located visually before any elevators present upon entering from the main entrance". Add: "Clearly visible from the building’s main entrance, main entry check-point (e.g., welcome/reception desk), the edge of its main lobby, or edge of its main welcome area, or are located visually before any elevators present upon entering from the main entrance" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Add: ", or the maximum allowable by local code" after "between handrails" |
27 Apr, 2017 |
Alternative Adherence Path |
Type: Alternative Adherence Path
Post Date: 27 Apr, 2017 Projects that have significantly progressed through or have completed development, design, and/or planning processes may be exempt from Part 2 and may still achieve credit for this feature if achieving Parts 1 and 3. Projects pursuing this AAP are required to submit documentation that demonstrates significant hardship, such as financial or scheduling implications, in order to be exempt from Part 2. |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: ", including, decorative painting" after "Artwork" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 24 Oct, 2016 Change the first line of Part 1 from "The following requirements are met for at least one common staircase:" to "In projects of 2 to 4 floors, at least one common staircase meets the following requirements:" |
24 Oct, 2016 |
Amendment |
Type: Amendment
Post Date: 24 Oct, 2016 Change the first line of Part 3 from "Both common stairs and paths of frequent travel display elements of aesthetic appeal in incorporating at least 2 of the following:" to "In projects of 2 to 4 floors, common stairs, entryways and corridors display elements of aesthetic appeal by incorporating at least 2 of the following:" |
24 Oct, 2016 |
Intent |
Type: Intent
Post Date: 24 Oct, 2016 In the Feature description, remove the second paragraph. Replace with the following text: |
24 Oct, 2016 |
Amendment |
Type: Amendment
Post Date: 06 May, 2016 Change “In projects of 2 to 4 floors, at least one staircase meets the following requirements:” to “In projects of 2 to 4 floors, at least one common staircase meets the following requirements:” |
06 May, 2016 |
Amendment |
Type: Amendment
Post Date: 06 May, 2016 Change “Both stairs and paths of frequent travel…” to “Both common stairs and paths of frequent travel…” |
06 May, 2016 |
Alternative Adherence Path |
Type: Alternative Adherence Path
Post Date: 06 May, 2016 Staircases located in residential units may be exempt from meeting the requirements of Part 2c (stair width set at a minimum of 1.4m [56 in] between handrails. |
06 May, 2016 |
Amendment |
Type: Amendment
Post Date: 06 May, 2016 Change “The following requirements are met:” to “The following requirements are met for at least one common staircase:” |
06 May, 2016 |
Type | Description | Post Date |
---|---|---|
Amendment |
Type: Amendment
Post Date: 26 Jul, 2017 For AAP with post date 27 Apr 2017, after "Comprehensive corporate wellness programs...engagement or active commuting", remove: Add: "Updated from AAP with post date 1 Jul, 2016" |
26 Jul, 2017 |
Amendment |
Type: Amendment
Post Date: 26 Jul, 2017 For AAP with post date 27 Apr, 2017, after "Incentives for employees...with Feature 65", remove: Add: "Updated from AAP with post date 24 Oct, 2016." |
26 Jul, 2017 |
Amendment |
Type: Amendment
Post Date: 26 Jul, 2017 For AAP with post date 27 Apr 2017, after "Comprehensive corporate wellness programs...engagement or active commuting", remove: Add: "Updated from AAP with post date 1 Jul, 2016" |
26 Jul, 2017 |
Alternative Adherence Path |
Type: Alternative Adherence Path
Post Date: 27 Apr, 2017 Updated: Existing (Removed): |
27 Apr, 2017 |
Alternative Adherence Path |
Type: Alternative Adherence Path
Post Date: 27 Apr, 2017 Updated: Existing (Removed): |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "Incentives that encourage greater levels of physical activity through reimbursement of gym memberships or other means of physical activity can help people develop and maintain regular exercise routines and achieve greater fitness levels". |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "A plan with at least 2 of the following is developed and implemented". Add: "At least two of the following are implemented for all full-time employees" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "a. Tax-exempt payroll deductions relating to bicycle commuting and mass transit (such as the |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "b. $200 or greater reimbursements or incentive payments in every 6-month period that an employee |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "c. A subsidy of at least $240 per year is available to each interested employee to cover the costs of |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "d. A subsidy of at least $240 per year is available to employees to cover the costs of fitness or training |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "e. A subsidy of at least $50 per year is available to employees to cover the costs of a bicycle share |
27 Apr, 2017 |
Alternative Adherence Path |
Type: Alternative Adherence Path
Post Date: 17 Jan, 2017 As an alternative to one of the activity incentives provided under Feature 65, Part 1: Activity Incentive Programs, projects may create company sponsored sports teams, provided the sports teams are selected by the employees and the owner will accommodate similar incentives for alternatives upon employee request. |
17 Jan, 2017 |
Intent |
Type: Intent
Post Date: 24 Oct, 2016 In the Feature description, remove the second paragraph. Replace with the following text: |
24 Oct, 2016 |
Verification type |
Type: Verification type
Post Date: 24 Oct, 2016 Under Appendix D, change the feature type for Part 1 from "(Protocol)" to "(Organizational Protocol)" |
24 Oct, 2016 |
Type | Description | Post Date |
---|---|---|
Amendment |
Type: Amendment
Post Date: 26 Jul, 2017 In part title, remove: "Professional" |
26 Jul, 2017 |
Amendment |
Type: Amendment
Post Date: 26 Jul, 2017 Add: "from a qualified professional" after "The following is offered" |
26 Jul, 2017 |
Intent |
Type: Intent
Post Date: 24 Oct, 2016 In the Feature description, remove the second paragraph. Replace with the following text: |
24 Oct, 2016 |
Verification type |
Type: Verification type
Post Date: 24 Oct, 2016 Under Appendix D, change the feature type for Parts 1 and 2 from "(Protocol)" to "(Organizational Protocol)" |
24 Oct, 2016 |
Type | Description | Post Date |
---|---|---|
Alternative Adherence Path |
Type: Alternative Adherence Path
Post Date: 26 Jul, 2017 Projects may use Option 1. Surround Density of the LEED BD+C Surrounding density and diverse uses Credit to comply with Part 3: Neighborhood Connectivity. Documentation must demonstrate that the project is located on a site where the surrounding density within 400 m [1/4 mi] of the project boundary has a minimum combined density of at least 5,050 m²/hectare [22,000 ft²/acre] of buildable land, a minimum residential density of 7 dwelling units (DU) per hectare [17.5 DU/acre), or a minimum nonresidential density (FAR) of 0.5. |
26 Jul, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Add: "and plazas" after "walking paths" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Add: "or open air courtyard" after "b. A plaza" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Add: "or other landscaped elements" after "c. A garden" |
27 Apr, 2017 |
Amendment |
Type: Amendment
Post Date: 27 Apr, 2017 Remove: "The project is eligible for at least 3 points in the LEED BD+C: New Construction "Surrounding |
27 Apr, 2017 |
Intent |
Type: Intent
Post Date: 24 Oct, 2016 In the Feature description, remove the second paragraph. Replace with the following text: |
24 Oct, 2016 |
Verification type |
Type: Verification type
Post Date: 10 Feb, 2016 Add Owner Letters of Assurance as required documentation, remove Architect Letter of Assurance. |
10 Feb, 2016 |