Feature 10: Pesticide management

Type Description
Equivalency
Type: Equivalency
Post Date: 21 Aug, 2017

Biopesticides registered with the Central Insecticides Board and Registration Committee (CIBRC) of India has been accepted as an alternative for the requirements of Feature 10 Part 1b.


Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Remove: "The following conditions are met for all pesticides and herbicides used on outdoor plants". Add: "Pesticide and herbicide use on outdoor plants is eliminated, or hazards are minimized through one of the following:"


Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Remove: "Pestcide and herbicide use is minimized by creating a use plan based on Chapter 3 of the San Francisco Environment Code Integrated Pest Management (IPM) program". Add: "The creation of a pest management plan in place of pesticide/herbicide use, based on Chapter 3 of the San Francisco Environment Code Integrated Pest Management (IPM) program"


Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Remove: "Only pesticides with a hazard tier ranking of 3 (least hazardous) as per the City of San Francisco Department of the Environment's (SFE) Hazard Tier Review Process are used. Refer to Table A2 in Appendix C for more details". Add: "Use of hazard-ranked pesticides based on screening lists described in Table A2 in Appendix C."


Equivalency
Type: Equivalency
Post Date: 17 Jan, 2017

The UK Regulations Directive 2009/128/EC has been approved for F10, Part 1, Requirement a. Adopting organic farming principles described in Council Regulation (EC) No 834/2007 of 28 June 2007 has been approved as an acceptable method to comply with F10 Part 1, Requirement b.
Note that:
1. Any envisaged exemptions adopted from the SF IPM program has to be listed.
2. The public has to be notified of any pesticides use under exempt conditions
3. Annual update of the IPM plan
4. Display the IPM plan in the building communal area and/or on website
5. Engage organic gardening professional for design of landscaping, and if infestation occurs
6. Ensure that ongoing use of IPM is part of any FM contract that manages the landscaping


Amendment
Type: Amendment
Post Date: 24 Oct, 2016

Under Part 1b, remove "Reduced Risk Pesticide List" and replace with "Hazard Tier Review Process"


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To reduce the presence of pests in buildings and minimizing occupant exposure to harmful chemicals.'


Amendment
Type: Amendment
Post Date: 06 May, 2016

In Part 1 description, change “The following conditions are met for all pesticides and herbicides used on plants:” to “The following conditions are met for all pesticides and herbicides user on outdoor plants.”


Feature 11: Fundamental material safety

Type Description
Equivalency
Type: Equivalency
Post Date: 05 Oct, 2017

The Dutch Working Conditions Legislation (including the Decree, Act, and Regulation) has been approved as an alternative to AHERA for Feature 11, Part 3. Note that projects must maintain a copy of the records produced by the asbestos investigator/abatement contractor, which should be made available to the building occupants.


Equivalency
Type: Equivalency
Post Date: 05 Oct, 2017

PCB directive NRW- RdErl. d. Ministry of construction and housing v. 3.7.1996 - II B 4 - 476.101 has been accepted as an alternative for the requirements of Feature 11 Part 4a.


Equivalency
Type: Equivalency
Post Date: 21 Aug, 2017

Asbestos inspection every three years through an agency/lab accredited by the 'National Accreditation Board for Testing and Calibration Laboratories (NABL), India' has been accepted as an alternative to the requirements of Feature 11 Part 3a.
An on-site investigation of the commercial space conducted by an agency/lab accredited by the 'National Accreditation Board for Testing and Calibration Laboratories (NABL), India', has been accepted as an alternative to the requirements of Feature 11 Part 2a. Note that projects must maintain a copy of the records produced by the asbestos investigator/abatement contractor, which should be made available to the building occupants.


Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Remove: "Not more than 100 ppm (by weight) added lead". Add: "Not more than a weighted average of 0.25% lead in wetted surfaces of pipes, pipe fittings, plumbing fittings, and fixtures, and 0.20% for solder or flux used in plumbing for water intended for human consumption"


Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Add "c. Not more than 100 ppm (by weight) added lead in all other building materials."


Equivalency
Type: Equivalency
Post Date: 17 Jan, 2017

The New York Department of Environmental Protection Asbestos Control Program and Asbestos Rules and Regulations has been approved as an equivalent to AHERA for Feature 11, Part 3.
Note that projects must maintain a copy of the records produced by the asbestos investigator/abatement contractor, which should be made available to the building occupants.


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To reduce or eliminate occupant exposure to lead, asbestos, and PCBs from building materials.'


Verification type
Type: Verification type
Post Date: 10 Feb, 2016

Add MEP Letter of Assurance as required documentation.


Verification type
Type: Verification type
Post Date: 10 Feb, 2016

Add policy document as required documentation, remove Architect Letter of Assurance.


Feature 12: Moisture management

Type Description
Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To limit the potential for bacteria and mold growth within buildings from water infiltration and condensation.'


Feature 13: Air flush

Type Description
Amendment
Type: Amendment
Post Date: 26 Jul, 2017

For Part 1a, remove: "4,500 m³ of outdoor air per m²". Add: "4,266 m³ of outdoor air per m²"


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To remediate construction-related indoor air contamination.'


Amendment
Type: Amendment
Post Date: 06 May, 2016

In Part 1b, change “0.3 CFM fresh air per ft² of floor area” to “0.3 CFM outdoor air per ft² of floor area”


Feature 14: Air infiltration management

Type Description
Equivalency
Type: Equivalency
Post Date: 26 Jul, 2017

Previously published as AAP:
The ISO 9972-2015 - Thernal performance of buildings - Determination of air permeability of buildings - Fan Pressurization method is an acceptable alternative to meet WELL Feature 14 Part 1a.


Equivalency
Type: Equivalency
Post Date: 22 May, 2017

The ISO 9972-2015 - Thernal performance of buildings - Determination of air permeability of buildings - Fan Pressurization method, is an acceptable alternative to meet WELL Feature 14 Part 1a.


Equivalency
Type: Equivalency
Post Date: 24 Oct, 2016

The Green Star Innovation Challenge: Air tightness testing is an accepted equivalent to Feature 14: Air Infiltration Management. Compliance with the Green Star credit is sufficient to comply with the WELL feature.


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To minimize air quality and thermal comfort issues resulting from the infiltration of untreated air through the building envelope.'


Equivalency
Type: Equivalency
Post Date: 26 Jul, 2016

Previously published as AAP:
In lieu of performing envelope commissioning in accordance with ASHRAE Guideline 0-2005 and NIBS Guideline 3-2012 for new construction or structural renovation), the project may complete a thermographic survey, airtightness test, and inspection and correction of defects in accordance with ATTMA TSL2 guidelines.


Feature 15: Increased ventilation

Type Description
Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Remove: "The following is required in terms of the rate of outdoor air supply to all regularly occupied spaces". Add: "One of the following is required in all regularly occupied spaces"


Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Remove: "Exceed ASHRAE outdoor air supply rates met in the WELL Ventilation Effectiveness feature by 30%". Add: "Exceed outdoor air supply rates met in Feature 03, Part 1a by 30%".


Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Add: "b. Follow CIBSE AM10, Section 4, Design Calculations, to predict that room-by-room airflows will provide effective natural ventilation."


Equivalency
Type: Equivalency
Post Date: 27 Apr, 2017

CEN Standards EN 15251:2007 and EN 13779:2007 may be used in lieu of ASHRAE 62.1-2013 for Feature 15, Part 1. ​​​​

The project must meet Category I ​or II​ (described in Table 1)​ and must calculate the ventilation rate based on ​either of the below calculation methods​,​ referenced in EN 15251: 2007​, ​section B.1.3​ ""Method based on ventilation rate per person or per m² floor area​:"" ​
​1​) the addition of the ​occupant and building ​values ​(see section B.1.2)
2​) the highest value (maximum of the calculated value based on per person and the value based on per m² floor area from Table B.3)

​Additionally, the requirements of CEN Standard EN 15251-2007 must be met and the performance requirements of CEN Standard EN 13779:2007 related to ventilation and room conditioning systems must be met (excluding section 7.3, Thermal Environment; section 7.6, Acoustic Environment; section A.16; and section A.17).


Equivalency
Type: Equivalency
Post Date: 24 Oct, 2016

AS 1668.2 may be used in lieu of ASHRAE 62.1 for Feature 15, Part 1. Note that projects that wish to comply with AS 1668.2 must increase ventilation by 50% rather than the 30% increase required when complying with ASHRAE 62.1.


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To expel internally-generated pollutants through an increased supply of outdoor air.'


Amendment
Type: Amendment
Post Date: 06 May, 2016

Change Part name from "Increased Fresh Air Supply" to "Increased Outdoor Air Supply"


Amendment
Type: Amendment
Post Date: 06 May, 2016

In Part 1, change "The following is required in terms of the rate of fresh air supply to all regularly occupied spaces:" to "The following is required in terms of the rate of outdoor air supply to all regularly occupied spaces:"


Amendment
Type: Amendment
Post Date: 06 May, 2016

In Part 1a, change “Exceed ASHRAE fresh air supply rates…” to “Exceed ASHRAE outdoor air supply rates…”


Feature 16: Humidity control

Type Description
Equivalency
Type: Equivalency
Post Date: 21 Aug, 2017

Projects situated in countries where local or regional standards do not pose strict requirements for relative humidity control (e.g. EN-15251) cannot earn points by not complying with the requirements of Feature 16, Part 1. Projects without dehumidification or humidification systems may earn points through Part 1b.


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To limit the growth of pathogens, reduce off-gassing, and maintain thermal comfort by providing the appropriate level of humidity.'


Feature 17: Direct source ventilation

Type Description
Equivalency
Type: Equivalency
Post Date: 21 Aug, 2017

Low emission criteria of EPEAT has been accepted as an alternative to Ecologo CCD 035, Blue Angel RAL- UZ 171 or Green Star in Feature 17 Part 1.


Amendment
Type: Amendment
Post Date: 17 Jan, 2017

Under Part 1, change the beginning of the first line to 'All cleaning and chemical storage units, all bathrooms and all rooms that contain printers and copiers…"


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To preserve air quality in occupied spaces through the isolation and proper ventilation of indoor pollution sources and chemical storage areas.'


Verification type
Type: Verification type
Post Date: 10 Feb, 2016

Add annotated mechanical and architectural drawing as required documentation, remove MEP Letter of Assurance, remove on-site spot checks.


Feature 18: Air quality monitoring and feedback

Type Description
Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Add: "(measured at 1.2-1.8 m [4-6 ft] above the floor)" after "once an hour"


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To monitor and effectively remediate indoor air quality issues and inform building managers and occupants of the quality of the indoor environment.'


Alternative Adherence Path
Type: Alternative Adherence Path
Post Date: 06 May, 2016

In projects with strict data privacy requirements, the requirements of Part 3 (Environmental Measures Display) may be met by hosting the required data on a website accessible to occupants and in locations where the physical display would be located, placing signage indicating the website where the data may be accessed.


Amendment
Type: Amendment
Post Date: 06 May, 2016

In Part 1 description, change “Monitors measure 2 of the following pollutants in a regularly occupied space…” to “Monitors measure 2 of the following pollutants in a regularly occupied or common space…”


Verification type
Type: Verification type
Post Date: 10 Feb, 2016

Add on-site spot checks as required verification.


Feature 19: Operable windows

Type Description
Alternative Adherence Path
Type: Alternative Adherence Path
Post Date: 27 Apr, 2017

For Feature 19, Part 1, a dedicated outdoor terrace can be provided. The terrace must satisfy the following requirements:
a. Must be directly accessible from the tenant space
b. Must be able to accommodate a minimum of 15% of the total regular project occupants
c. Must be adequately shaded to allow occupants to perform their work without significant glare
d. Feature 19, Part 2 and Part 3 must be addressed


Alternative Adherence Path
Type: Alternative Adherence Path
Post Date: 17 Jan, 2017

To fulfill Feature 19, Part 1, projects may provide operable windows to 95% of the regularly occupied spaces (by floor area) in the office, provided that regularly occupied spaces, which do not have windows, have larger doorways to allow fresh air in, when open.


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To increase the supply of high quality outdoor air and promote a connection to the outdoor environment by encouraging occupants to open windows when outdoor air quality is acceptable.'


Amendment
Type: Amendment
Post Date: 06 May, 2016

Change “Every regularly occupied space has operable windows that provide access to fresh air…” to “Every regularly occupied space has operable windows that provide access to outdoor air…”


Verification type
Type: Verification type
Post Date: 10 Feb, 2016

Add Architect Letter of Assurance as required documentation, remove annotated architectural drawing.


Verification type
Type: Verification type
Post Date: 10 Feb, 2016

Add policy document as required documentation, remove Architect Letter of Assurance.


Verification type
Type: Verification type
Post Date: 10 Feb, 2016

Add Owner Letter of Assurance as required documentation, remove Architect Letter of Assurance.


Feature 20: Outdoor air systems

Type Description
Amendment
Type: Amendment
Post Date: 26 Jul, 2017

For Part 1b, remove: "all applicable ASHRAE standards and codes". Add: "ventilation standards used in Feature 03 Ventilation effectiveness"


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To allow buildings to control the outdoor air supply independently from the heating/cooling needs of the building.'


Feature 21: Displacement ventilation

Type Description
Equivalency
Type: Equivalency
Post Date: 21 Aug, 2017

REHVA Guidebook No. 1 (Displacement Ventilation in non-industrial premises) may be used in lieu of the System Performance Evaluation and ASHRAE Guidelines RP-949 for Feature 21, Part 1.


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To improve air quality in the breathing zone of the room and maintain thermal comfort by supplying low velocity outdoor air near the floor and expelling near the ceiling.'


Amendment
Type: Amendment
Post Date: 06 May, 2016

Replace “One of the following is met for projects implementing a displacement ventilation system for heading and/or cooling:” with “Projects implement a displacement ventilation system for heating and/or cooling in which one of the following is met:”


Feature 22: Pest control

Type Description
Alternative Adherence Path
Type: Alternative Adherence Path
Post Date: 27 Apr, 2017

When desk bins are used to comply with Feature 22, Part 1, Requirement b, waste must be emptied at least once per day. Bins must be lined with appropriate liners (e.g. biodegradable liners for the compost bin) that will sufficiently retain all waste and waste residue. Bins must be wiped to remove waste residue when present or at least weekly.


Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Remove: "Inspections". Add: "Visual inspections during performance verification"


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To reduce the presence of pests in buildings and minimize occupant exposure to pest-related allergens.'


Verification type
Type: Verification type
Post Date: 06 May, 2016

Change Part 1 verification type from Visual Inspection to Operations Schedule and Spot Check.


Alternative Adherence Path
Type: Alternative Adherence Path
Post Date: 06 May, 2016

Inquiry: For Part 1b, our garbage cans are integrated into casework. The casework has a 6 inch opening at the top for users to insert waste. The garbage is collected from the garbage cans daily to minimize the time that waste remains in the garbage cans. Will this design meet the requirements of Part 1b?

Ruling: No, the design as described is not approved. The openings are large enough to allow pests to gain access to the garbage and allow for discarded trash to fall outside the garbage receptacle within the casework.


Amendment
Type: Amendment
Post Date: 10 Feb, 2016

In introduction language, remove "and furniture be covered in washable covers" from the last sentence in the second paragraph. The last sentence becomes: "To minimize allergenic pests, this feature requires that pest inspections be conducted regularly and food be stored and sealed."


Feature 23: Advanced air purification

Type Description
Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To improve recirculated indoor air quality through the implementation of advanced air purification strategies.'


Feature 24: Combustion minimization

Type Description
Equivalency
Type: Equivalency
Post Date: 21 Aug, 2017

The emission standards of Central Pollution Control Board (Government of India) has been accepted as an alternative for California’s South Coast Air Quality Management District rules for pollution in Feature 24 Part 2. However, combustion equipment for which there are no CPCB emission standards must meet California’s South Coast Air Quality Management District rules for pollution.
The following are acceptable alternatives to the requirements of Feature 24 Part 4

  • Emission standards as per Bharat Stage III for Feature 24 Part 4 a
  • Emission standards as per Bharat Stage III or IV for Feature 24 Part 4 b

Equivalency
Type: Equivalency
Post Date: 07 Apr, 2017

The following equivalencies have been approved for Feature 24 Part 4:
1. Non-road diesel engine vehicles - Euro Stage IIIA, US Tier 3 and 2, Japan MoE standards.
2. On road diesel engine vehicles - Euro V (2012) standard.
It should be noted that Euro Stage IIIA, US Tier 3 and 2, Japan MoE and Euro V (2012) standard's allowable emission levels exceed those required in US Tier 4 and US EPA 2007. However, Euro Stage IIIA, US Tier 3 and 2, Japan MoE and Euro V are currently deemed best in class within Hong Kong at this time.
It should be noted that Euro Stage IIIA, US Tier 3 and 2, Japan MoE and Euro V (2012) standard's allowable emission levels exceed those required in US Tier 4 and US EPA 2007. However, Euro Stage IIIA, US Tier 3 and 2, Japan MoE and Euro V are currently deemed best in class within Hong Kong at this time.


Equivalency
Type: Equivalency
Post Date: 20 Mar, 2017

The following European local emission standards have been approved as an acceptable equivalent for Feature 24, Part 4:
1. European Stage IV standard for non-road diesel engine vehicles or the use of non-road diesel engine vehicles equipped with diesel particulate filters (DPF).
2. Euro VI emission standards for on-road engine vehicles or the use of on-road diesel engine vehicles equipped with diesel particulate filters (DPF).


Alternative Adherence Path
Type: Alternative Adherence Path
Post Date: 17 Jan, 2017

Projects that wish to include a gas range within the project scope must provide range hoods with increased exhaust efficiency in order to exhaust combustion byproducts. The range hood must provide at least 100 cubic feet per minute of exhaust air for every 10,000 BTU’s of burner output. If the burner output is unknown or cannot be guaranteed, then the range hood should provide a minimum of 600 cubic feet per minute of exhaust air. In addition, the range hood shall be exhausted directly to the outdoors.


Equivalency
Type: Equivalency
Post Date: 17 Jan, 2017

The following China local standards have been approved as an acceptable alternative for F24, Part 4:
1. China local standard GB20891-2014 for non-road diesel engine vehicles
2. China local standard GB17691-2005 for passenger vehicles and heavy duty trucks
Note that that NOx limits in the China standards are higher then US EPA limits.


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To reduce occupant exposure to combustion-related air pollution from heating and transportation sources.'


Verification type
Type: Verification type
Post Date: 10 Feb, 2016

Add Owner Letter of Assurance as required documentation, remove Architect Letter of Assurance.


Feature 25: Toxic material reduction

Type Description
Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Remove: "(Please refer to Table A3 for additional details.)"


Amendment
Type: Amendment
Post Date: 24 Oct, 2016

To the last line of the first paragraph of the feature description, add: "All parts of this feature only apply to materials installed inside the weather proofing membrane of a project. (Please refer to Table A3 for additional details)"


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To minimize the impact of hazardous building material chemicals on indoor air quality and protect the health of manufacturing and maintenance workers.'


Verification type
Type: Verification type
Post Date: 10 Feb, 2016

Add Owner Letter of Assurance as required documentation.


Verification type
Type: Verification type
Post Date: 10 Feb, 2016

Add Contractor Letters of Assurance as required documentation.


Feature 26: Enhanced material safety

Type Description
Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Remove: "At least one of the following requirements is met". Add: "At least 25% of products by cost (including furnishings, built-in furniture, all interior finishes and finish materials) meet one or more of the following requirements"


Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Remove: "The project completes all Imperatives in the Materials Petal under the Living Building Challenge 3.0". Add: "Have a Declare: Living Building Challenge Red List Free, Declare: Living Building Challenge Compliant, or Living Product Challenge label"


Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Remove: "At least 25% of products by cost (including furnishings, built-in furniture, all interior finishes and finish materials) are Cradle to Cradle™ Material Health Certified with a V2 Gold or Platinum or V3 Bronze, Silver, Gold or Platinum Material Health Score". Add: "Have a Cradle to Cradle™ Material Health Certified with a V2 Gold or Platinum or V3 Bronze, Silver, Gold or Platinum Material Health Score."


Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Remove: "At least 25% of products by cost (including furnishings, built-in furniture, all interior finishes and finish materials) have no GreenScreen® Benchmark 1, List Translator 1 or List Translator Possible 1 substances over 1,000 ppm, as verified by a qualified Ph.D. toxicologist or Certified Industrial Hygienist". Add: "Have no GreenScreen® Benchmark 1, List Translator 1 or List Translator Possible 1 substances over 1,000 ppm, as verified by a qualified Ph.D. toxicologist or Certified Industrial Hygienist"


Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Remove: "At least 25% of products by cost (including furnishings, built-in furniture, all interior finishes and finish materials) meet some combination of the certifications described in requirements b and c".


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To minimize the impact of hazardous building material ingredients on indoor air quality and protect the health of manufacturing and maintenance workers.'


Verification type
Type: Verification type
Post Date: 10 Feb, 2016

Add Contractor Letter of Assurance as required documentation, add Owner Letter of Assurance as required documentation.


Feature 27: Antimicrobial activity for surfaces

Type Description
Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Remove: "that has an output of at least 4 mW/cm²" after "UV cleaning device"


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To reduce occupant exposure to both harmful pathogens and hazardous cleaning agents.'


Verification type
Type: Verification type
Post Date: 10 Feb, 2016

Add annotated architectural drawing or operations schedule as required documentation, remove architect Letter of Assurance.


Feature 28: Cleanable environment

Type Description
Amendment
Type: Amendment
Post Date: 27 Apr, 2017

Remove: "Free of sharp internal angles, corners and crevices". Add: "Free of crevices and other hard-to-reach places"


Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To reduce occupant exposure to pathogens on high-touch surfaces.'


Verification type
Type: Verification type
Post Date: 10 Feb, 2016

Add on-site spot checks as required verification.


Verification type
Type: Verification type
Post Date: 10 Feb, 2016

Add Contractor Letters of Assurance as required documentation.


Feature 29: Cleaning equipment

Type Description
Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To reduce occupant exposure to both harmful pathogens and hazardous chemicals through the use of high quality cleaning equipment and the proper storage of cleaning agents.'


Amendment
Type: Amendment
Post Date: 10 Feb, 2016

Remove Part 1b. Update part lettering by changing “c. Mops do not have to be wrung by hand.” to “b. Mops do not have to be wrung by hand”, and changing "d. Vacuum cleaners contain filters with a HEPA rating." to "c. Vacuum cleaners contain filters with a HEPA rating."


Feature 30: Fundamental water quality

Type Description
Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To limit the presence of sediment and water-borne pathogens in water designated for human contact.'


Amendment
Type: Amendment
Post Date: 06 May, 2016

In Part 1, change “Turbidity of the water sample is less than 0.3 NTU” to “Turbidity of the water sample is less than 1.0 NTU”.


Feature 31: Inorganic contaminants

Type Description
Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To limit the presence of inorganic contaminants in drinking water.'


Amendment
Type: Amendment
Post Date: 06 May, 2016

Change “All water being delivered to the project area for human consumption meets the following limits:” to “All water being delivered to the project area for human consumption (at least one water dispenser per project) meets the following limits:


Feature 32: Organic contaminants

Type Description
Intent
Type: Intent
Post Date: 24 Oct, 2016

In the Feature description, remove the second paragraph. Replace with the following text:
'Intent: To limit the presence of organic contaminants in drinking water.'


Amendment
Type: Amendment
Post Date: 06 May, 2016

Change “All water being delivered to the project area for human consumption meets the following limits:” to “All water being delivered to the project area for human consumption (at least one water dispenser per project) meets the following limits:


Feature 33: Agricultural contaminants

Type Description
Amendment
Type: Amendment
Post Date: 26 Jul, 2017

Remove "Nitrate less than 10 mg/L nitrogen". Add "Nitrate less than 50 mg/L (10 mg/L as nitrogen)"