Asbestos Content and Advocacy
All newly-installed building materials do not contain asbestos >1% by weight in the below materials. Wherever procurement of a product or a material not possible, the project is permitted to submit documentation demonstrating an attempt has been made, including a petition or formal request filed with at minimum 3 manufacturers (per product or material) who were unable to meet their needs.
- Thermal insulation (applied to pipes, fittings, boilers, breeching, tanks, or ducts)
- Acoustical plaster
- Fireproofing materials on structural members
- Wallboard/millboard
- Floor tile and sheeting
- Roofing and siding shingles (including metal cladding)
- Construction mastics
Lead Content
All newly-installed building materials meet the following material composition requirements:
- No more than a weighted average of 0.25% lead in wetted surfaces of pipes, pipe fittings, plumbing fittings, and fixtures, and 0.20% for solder or flux used in plumbing for water intended for human consumption.
- No interior or exterior paints containing lead.
- Use of lead-free roofing and flashing.
Lead Advocacy
For each product type listed below (as applicable) projects submit documentation demonstrating a petition or a formal request is filed with at least three manufacturers to limit lead content to <100ppm.
- Door hardware
- Ductwork
- Conduit
- Metal studs
- Mirrors
- Brass cooler drains, pumps, motors, valves
- Vinyl blinds or wallcovering
Lead Disclosure
Project teams file a petition with the US Consumer Product Safety Commission requesting a product label is developed for building products to verify lead content is below 100ppm.